Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Reliability of marginal bone level measurements on digital panoramic and digital intraoral radiographs
Kristina Hellén-Halme1, Agneta Lith2, Xie-Qi Shi3
1Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden. Kristina.Hellen-Halme@mau.se.
Objectives:
The aim of this study was to evaluate the reliability of bitewing and panoramic radiographs in marginal bone level measurements in terms of inter- and intra-observer agreement.
Methods:
Fifty paired bitewing and panoramic images were used. Eight observers measured marginal bone level at the mesial and distal surfaces of tooth 25 and tooth 35. Thus, in total 100 radiographs of 400 measurements were obtained for each observer. To evaluate intra-observer agreement, three observers re-evaluated the radiographs after a minimum of 1 month. Intra-class correlation coefficient (ICC) was applied to evaluate the inter- and intra-observer agreement. The t test was applied to assess possible difference in measurement between bitewing and panoramic radiographs.
Results:
The mean ICC value of inter-observer agreement was 0.85 for bitewing and 0.66 for panoramic radiographs. The mean intra-observer agreement was 0.92 and 0.76 for bitewing and panoramic radiographs, respectively. There was no statistically significant difference between bitewing and panoramic radiographs in measurements of marginal bone level on maxillary tooth 25, whereas a statistically significant difference was found between the two image modalities on mandible tooth 35.
Conclusion:
Bitewing examination should be the choice of image modality for assessment of marginal bone level at premolar region due to good to excellent reliability and low radiation dose. However if a panoramic radiograph already exists, a rough estimation of marginal bone level at premolar region is clinically acceptable bearing in mind that the bone height of the mandible premolar region might be overestimated as compared to bitewing radiograph.
Related Concept Videos
Social Foundations of Self IV: Self in Digital Communication
Reliability and Validity
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...

