Comparison of Two Thrombin Generation Methods, CAT and ST-Genesia, in Liver Transplant Patients
Stéphanie Roullet1,2, Sylvie Labrouche3,4, Geneviève Freyburger3
1CHU Bordeaux, Service d'Anesthésie-Réanimation Pellegrin, Bordeaux, France.
Background:
During liver transplantation (LT), thrombin generation (TG) is altered. The most frequently used assay for TG is the Calibrated Automated Thrombogram (CAT). It is designed for series of plasmas and is semi-automated. Complete automation has led to a new device, the ST-Genesia, enabling quantitative standardized TG evaluation.
Objective:
The aim of this observational study was to compare the TG results of the CAT and the ST-Genesia on frozen-thawed plasma samples prepared from the blood of LT patients.
Patients And Methods:
Poor platelet plasma aliquots were prepared from blood samples from six LT patients selected to get the whole range of TG and were assessed with CAT (recombinant human tissue factor [TF] concentration 5 pm) and with ST-Genesia Bleedscreen assay (BS, using 'low' recombinant human TF concentration) and Thromboscreen assay (TS, using 'medium' recombinant human TF concentration). The TG parameters studied were: lag time, peak, time to peak, endogenous thrombin potential, velocity index and start tail.
Results:
BS and TS did not differ significantly from each other whatever the parameter studied, whereas most of the CAT parameters were significantly different from those obtained with BS and TS. Hierarchical clustering analysis of the different parameters of TG showed three homogeneous groups. One cluster gathered TG quantitative parameters from ST-Genesia. A second cluster gathered all the kinetic parameters. The last cluster isolated the quantitative parameters of CAT.
Conclusion:
In patients undergoing LT, TG performed with CAT and with ST-Genesia provided different results, for unknown reasons.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits