Related Concept Videos

Instrument Transformers01:23

Instrument Transformers

457
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
457
Instrument Calibration01:12

Instrument Calibration

697
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
697
Instrumentation Amplifier01:25

Instrumentation Amplifier

1.0K
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.0K
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

51.0K
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
51.0K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

1.1K
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
1.1K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

1.5K
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exercise-Induced Symptom Exacerbation and Adverse Events in Moderate-to-Severe Traumatic Brain Injury.

The Journal of head trauma rehabilitation·2025
Same author

Incidence and Associated Risk Factors for Falls in Adults Following Critical Illness: An Observational Study.

Critical care medicine·2025
Same author

Management of Osteoporosis in Parkinson's Disease: A Systematic Review of Clinical Practice Guidelines.

Movement disorders clinical practice·2024
Same author

Appraisal of Clinical Practice Guideline: World guidelines for falls prevention and management for older adults: a global initiative.

Journal of physiotherapy·2024
Same author

Participation experiences of young people with limb difference in sports and recreation in Australia: a qualitative study.

Disability and rehabilitation·2024
Same author

Functional performance of a vibrotactile sensory substitution device in people with profound vision loss.

Optometry and vision science : official publication of the American Academy of Optometry·2024
Same journal

A Video Protocol of a Randomized Controlled Clinical Trial - Electrochemotherapy of Cutaneous Metastases with Reduced Dose Bleomycin (BLESS Trial).

Journal of visualized experiments : JoVE·2026
Same journal

A Standardized Ex Vivo Porcine Oromucosal Model for Evaluating Peptide Fluxes.

Journal of visualized experiments : JoVE·2026
Same journal

Lightweight English Text Classification with Deep Learning Based on Complex System Theory.

Journal of visualized experiments : JoVE·2026
Same journal

Integrating Artificial Intelligence-Assisted Translation Support into English Courses: Effects on Translation Accuracy, Perceived Stress, and Anxiety.

Journal of visualized experiments : JoVE·2026
Same journal

A Toxin-Based Counter-Selection System for Markerless Gene Deletion and High-Density Tn5 Transposon Mutagenesis in Pectobacterium brasiliense.

Journal of visualized experiments : JoVE·2026
Same journal

Seamless Multimodal Human-Robot Communication: Integration Techniques in Human-Computer Interaction.

Journal of visualized experiments : JoVE·2026
See all related articles

Related Experiment Video

Updated: Jan 26, 2026

An Instrumented Pull Test to Characterize Postural Responses
12:18

An Instrumented Pull Test to Characterize Postural Responses

Published on: April 6, 2019

11.4K

An Instrumented Pull Test to Characterize Postural Responses.

Joy Tan1, Wesley Thevathasan2, Jennifer McGinley3

  • 1Department of Medical Bionics, The University of Melbourne; Department of Neurology, The Royal Melbourne Hospital.

Journal of Visualized Experiments : Jove
|April 23, 2019
PubMed
Summary
This summary is machine-generated.

This study introduces an instrumented pull test to accurately measure postural instability in Parkinson's disease. This new method improves upon the traditional pull test by quantifying responses and identifying confounds for better clinical insights.

More Related Videos

Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes
08:27

Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes

Published on: March 3, 2023

1.4K
In Vitro Characterization of Histone Chaperones using Analytical, Pull-Down and Chaperoning Assays
08:16

In Vitro Characterization of Histone Chaperones using Analytical, Pull-Down and Chaperoning Assays

Published on: December 29, 2021

3.2K

Related Experiment Videos

Last Updated: Jan 26, 2026

An Instrumented Pull Test to Characterize Postural Responses
12:18

An Instrumented Pull Test to Characterize Postural Responses

Published on: April 6, 2019

11.4K
Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes
08:27

Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes

Published on: March 3, 2023

1.4K
In Vitro Characterization of Histone Chaperones using Analytical, Pull-Down and Chaperoning Assays
08:16

In Vitro Characterization of Histone Chaperones using Analytical, Pull-Down and Chaperoning Assays

Published on: December 29, 2021

3.2K

Area of Science:

  • Neurology
  • Biomechanics
  • Medical Engineering

Background:

  • Postural instability is a common and disabling symptom in Parkinson's disease.
  • The traditional clinical pull test for assessing postural reflexes has limitations in reliability and scaling.
  • Accurate quantification of postural responses is crucial for understanding disease progression and treatment efficacy.

Purpose of the Study:

  • To develop and present an instrumented version of the pull test for precise quantification of postural responses.
  • To address the limitations of the traditional pull test in reliability and scaling.
  • To provide a tool for detecting early postural abnormalities, tracking changes over time, and evaluating therapeutic responses in Parkinson's disease.

Main Methods:

  • An instrumented pull test was developed, manually administering pulls while recording pull force.
  • A semi-portable motion tracking system was used to capture trunk and foot displacements.
  • Data analysis focused on quantifying distance traveled in millimeters and identifying variabilities like pull force.

Main Results:

  • The instrumented pull test provides precise, quantitative data on postural responses.
  • It captures variabilities such as pull force, allowing for the identification and statistical accounting of potential confounds.
  • The system generates intuitive data in millimeter units for easier interpretation.

Conclusions:

  • The instrumented pull test offers a more reliable and objective method for assessing postural instability in Parkinson's disease.
  • This tool has potential applications in early detection of postural deficits, longitudinal monitoring of patients, and evaluating treatment effectiveness.
  • Quantifying key variables enhances the diagnostic and prognostic value of the pull test.