Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
In vitro efficacy of three different implant surface decontamination methods in three different defect configurations
David Keim1,2, Katrin Nickles1,3, Bettina Dannewitz1,4
1Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Johann Wolfgang Goethe-University Frankfurt/Main, Frankfurt/Main, Germany.
Objectives:
Evaluation of in vitro efficacy of three different implant surface decontamination methods in a peri-implant bone defect model.
Material And Methods:
A total of 180 implants were stained with indelible red color and distributed to standardized peri-implant bone defect resin models with a circumferential defect angulation of 30°, 60°, or 90° (supraosseous defect). Sixty implants were assigned to each type of defect. All implants were cleaned by the same examiner. For each type of defect, 20 implants were cleaned for 2 min with one of 3 devices: curette (CUR), sonicscaler (SOSC), or air abrasion with glycine powder (APA). Thereafter, photographs were taken from both sides of each implant and the cumulative uncleaned implant surface area was measured by color recognition technique. Scanning electron micrographs (SEM) were examined to assess morphologic surface damages.
Results:
The cleaning efficacy as percent (%) of residual color was significantly different for each of the 3 defect angulations (p < 0.001) for each treatment device: 30° CUR: 53.44% > SOSC: 19.69% > APA: 8.03%; 60° CUR: 57.13% > SOSC: 11.4% > APA: 0.13%; and 90° CUR: 48.1% > SOSC: 13.07% > APA: 0.58%. The differences between the three different cleaning modalities within each defect type were also significant (p < 0.005). SEM micrographs showed no surface damages after the use of APA.
Conclusion:
Air powder abrasion is the most efficient (APA > SOSC > CUR) and less surface damaging treatment modality for each defect angulation in this in vitro model.
Related Concept Videos
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configuration of Multielectron Atoms
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Self-Efficacy