Related Experiment Video
Updated: Jan 26, 2026

Novel Whole-tissue Quantitative Assay of Nitric Oxide Levels in Drosophila Neuroinflammatory Response
Published on: December 4, 2013
A reliable fluorimetric method to screen the nitric oxide synthase inhibitors in 96 well plate
Saurabh Agrawal1, Rita Kumari1, Pratibha Mehta Luthra1
1Dr. BR Ambedkar Center for Biomedical Research, University of Delhi, Delhi, 110007, India.
Abstract:
In general, 4 amino-5-methylamino-2',7'-difluorescein diacetate (DAF-FM-DA) dye is used to detect nitric oxide in biological systems through cell imaging. In this study, we have used 96 well plate format to quantify nitric oxide using DAF-FM-DA through a multimode reader (or independently using fluorospectrometer) and could be visualized in a fluorescence microscope. Similar study otherwise will require a high-end instrument. The method has been validated to screen NOS inhibitors in the HEK 293T cell lines over-expressing the NOS isoforms. We observed that the method is very simple to use, adaptive, sensitive and most importantly it saves time. REAGENTS/TOOLS: Ethanol (70% [v/v] in distilled water), Nω-Nitro-l-arginine (l-NAME), 7-Nitro-Indazole (7-NI) (Sigma, St. Louis, MO), HEK 293T cell lines (National Centre for Cell Science (NCCS), Pune, India), DMEM (Himedia laboratories Pvt), Fetal Bovine Serum (FBS) (Invitrogen, Carlsbad, CA), 100 U/mL penicillin, and 0.1 mg/mL streptomycin in a 5% CO2 atmosphere. Hank's Balanced Salt Solution (HBSS) without Phenol Red of pH 7.4 was prepared with the following composition: NaCl, 8.0g, KCl, 0.4g, CaCl2, 0.14g, MgSO4⋅7H2O, 0.1g, MgCl2·6H2O, 0.1g, Na2HPO4·2H2O, 0.06g, KH2PO4, 0.06g, glucose, 1.0g, NaHCO3, 0.35g, H2O, to 1000 ml, Sterilized and refrigerated, Calcium Ionophore A23187 (Sigma Aldrich 52665-69-7) DAF-FM Di Acetate (Molecular Probes Life Technologies), and DAF-FM Di Aceatate was prepared as a stock solution (5 mM) in DMSO, divided into aliquots and stored at -20 °C, followed by dilution to the required concentration in HBSS buffer before use. EQUIPMENT: Neubauer chamber, Microtube centrifuges (1.5 mL), Micropipettors,10,100, and 1000 mL with corresponding tips, multimode reader (Tecan, Synergy-HT), inverted fluorescence microscope (Nikon, eclipse Ti-S), black flat bottom Microplates (96-well) (Corning 3603).
More Related Videos
08:10Measuring Oxidative Stress Resistance of Caenorhabditis elegans in 96-well Microtiter Plates
Published on: May 9, 2015
08:505/6th Nephrectomy in Combination with High Salt Diet and Nitric Oxide Synthase Inhibition to Induce Chronic Kidney Disease in the Lewis Rat
Published on: July 3, 2013
Related Concept Videos
Nitric Oxide Signaling Pathway
Reliability and Validity
ATP Synthase: Mechanism
ATP Synthase: Structure
Oxidation Numbers
Eukaryotic Transcription Inhibitors
Eukaryotic transcription inhibitors usually contain two distinct domains, a...