Thomas Czermak1, Stephanie Fichtner2
1Medizinische Klinik und Poliklinik I, Klinikum der Universität München, Marchioninistraße 15, 81377, München, Deutschland. thomas.czermak@med.uni-muenchen.de.
Managing patients with cardiac implantable electronic devices (CIEDs) requires careful consideration of electromagnetic interference. Modern CIEDs allow most procedures to be performed safely, with updated protocols reflecting new findings for perioperative care.
Area of Science:
- Cardiology
- Biomedical Engineering
- Medical Device Management
Background:
- Cardiac implantable electronic devices (CIEDs) present management challenges due to electromagnetic interference (EMI) risks in medical settings.
- Existing guidelines for perioperative CIED management often lack robust evidence and can be contradictory.
- Increasing complexity of modern CIEDs necessitates updated management strategies.
Purpose of the Study:
- To review and update perioperative management protocols for patients with CIEDs.
- To address the safety of procedures involving potential EMI, such as electrocauterization, extracorporeal shock wave lithotripsy, and physiotherapy.
- To provide a pragmatic approach to CIED management based on recent clinical observations and findings.
Main Methods:
- Review of recent studies and clinical observations regarding EMI in CIED patients.
- Analysis of the impact of specific procedures (electrocauterization, ESWL, physiotherapy) on CIED function.
- Development and presentation of an adapted perioperative CIED management protocol.
Main Results:
- Despite potential for EMI, most procedures, including intraoperative electrocauterization and extracorporeal shock wave lithotripsy, can be safely performed in patients with modern CIEDs.
- Older recommendations regarding severe interference risks are often not supported by current clinical data.
- Physiotherapy devices can pose EMI risks, necessitating coordination with CIED specialists.
Conclusions:
- Perioperative management of CIED patients can be pragmatically adapted based on current evidence, moving beyond outdated recommendations.
- Modern CIEDs are generally robust, allowing for safe execution of a wide range of medical procedures.
- Close collaboration between medical teams and CIED specialists is crucial for ensuring patient safety during procedures with potential EMI exposure.
Related Concept Videos
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
The Electromagnetic Spectrum
The Electromagnetic Spectrum
Interference and Diffraction
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Electromagnetic Waves