Assessing test-retest reliability of phase contrast MRI for measuring cerebrospinal fluid and cerebral blood flow

Ashwin R Sakhare1,2, Giuseppe Barisano2,3, Judy Pa1,2,3

  • 1Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California.

Abstract

Related Concept Videos

Cerebrospinal Fluid01:21

Cerebrospinal Fluid

Cerebrospinal fluid (CSF) is a colorless liquid that flows around the brain and the spinal cord, playing a vital role in the protection, support, and overall function of the central nervous system (CNS). CSF production, circulation, and absorption are tightly regulated processes essential for the brain and spinal cord to function properly.
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
5.6K
Reliability and Validity01:29

Reliability and Validity

Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.8K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
12.8K
Blood Flow01:29

Blood Flow

Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
75.7K
Steady Flow of a Fluid Stream01:27

Steady Flow of a Fluid Stream

Consider a control volume, such as a pipe with solid boundaries, through which fluid flows and changes direction due to the impulse exerted by the resulting force from the pipe walls. In steady flow, the mass of fluid entering the control volume at a given time, t, with velocity v1, is equal to the mass leaving after infinitesimal time dt, with velocity v2.
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
690
Measurement of Fluid Pressure01:16

Measurement of Fluid Pressure

Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
601