Related Experiment Video
Updated: Jan 25, 2026

Cell Block Preparation from Cytology Specimen with Predominance of Individually Scattered Cells
Published on: July 21, 2009
Consistency and reproducibility of next-generation sequencing in cytopathology: A second worldwide ring trial study
Pasquale Pisapia1, Umberto Malapelle1, Gianluca Roma2
1Department of Public Health, University of Naples Federico II, Naples, Italy.
Background:
Artificial genomic reference standards in a cytocentrifuge/cytospin format with well-annotated genomic data are useful for validating next-generation sequencing (NGS) on routine cytopreparations. Here, reference standards were optimized to be stained by different laboratories before DNA extraction and to contain a lower number of cells (2 × 105 ). This was done to better reflect the clinical challenge of working with insufficient cytological material.
Methods:
A total of 17 worldwide laboratories analyzed customized reference standard slides (slides A-D). Each laboratory applied its standard workflow. The sample slides were engineered to harbor epidermal growth factor receptor (EGFR) c.2235_2249del15 p.E746_A750delELREA, EGFR c.2369C>T p.T790M, Kirsten rat sarcoma viral oncogene homolog (KRAS) c.38G>A p.G13D, and B-Raf proto-oncogene, serine/threonine kinase (BRAF) c.1798_1799GT>AA p.V600K mutations at various allele frequencies (AFs).
Results:
EGFR and KRAS mutation detection showed excellent interlaboratory reproducibility, especially on slides A and B (10% and 5% AFs). On slide C (1% AF), either the EGFR mutation or the KRAS mutation was undetected by 10 of the 17 laboratories (58.82%). A reassessment of the raw data in a second-look analysis highlighted the mutations (n = 10) that had been missed in the first-look analysis. BRAF c.1798_1799GT>AA p.V600K showed a lower concordance rate for mutation detection and AF quantification.
Conclusions:
The data show that the detection of low-abundance mutations is still clinically challenging and may require a visual inspection of sequencing reads to detect. Genomic reference standards in a cytocentrifuge/cytospin format are a valid tool for regular quality assessment of laboratories performing molecular studies on cytology with low-AF mutations.
More Related Videos
08:52Improving Reproducibility to Meet Minimal Information for Studies of Extracellular Vesicles 2018 Guidelines in Nanoparticle Tracking Analysis
Published on: November 17, 2021
07:43Using 22C3 Anti-PD-L1 Antibody Concentrate on Biopsy and Cytology Samples from Non-small Cell Lung Cancer Patients
Published on: September 25, 2018
Related Concept Videos
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features....
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Trial and Error and Algorithm
Inertial Frames of Reference