Related Experiment Video
Updated: Jan 25, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Radiation dose measurements in a dental orthopantogram unit using indigenously developed optically stimulated
Pradip Kumar1,2, Sunil Dutt Sharma3, Rakesh Mohan Chandola4
1National Institute of Technology, Raipur, India.
Abstract:
Dental orthopantogram (OPG)/cone beam computed tomography (CBCT) scanners are gaining popularity due to their 3D imaging with multiplanar view that provides clinical benefits over conventional dental radiography systems. Dental OPG/CBCT provides optimal visualization of adjacent overlaying anatomical structures that will be superpositioned in any single projection. The characteristics of indigenously developed optically stimulated luminescence dosimeters, namely, aluminium oxide doped with carbon (Al2 O3 :C), lithium magnesium phosphate doped with terbium and boron (LiMgPO4 :Tb,B) and lithium calcium aluminium fluoride doped with europium and yttrium (LiCaAlF6 :Eu,Y) were evaluated for their use in dental dosimetry. The dose-response of these dosimeters was studied at X-ray energies 60 kV, 70 kV and 81 kV. Radiation doses were also measured using Gafchromic film for comparison. Radiation dose was measured at eight different locations of a polymethyl methacrylate (PMMA) head phantom including eyes. The optically stimulated luminescence (OSL) sensitivity of LiMgPO4 :Tb,B is about 1.5 times and LiCaAlF6 :Eu, is about 20 times higher than the sensitivity of Al2 O3 :C. It was found that measured radiation doses by the three optically stimulated luminescence dosimeters (OSLDs) and Gafchromic film in the occipital region (back side) of a PMMA phantom, were consistent but variations in dose at other locations were significantly higher. The three OSLDs used in this study were found to be suitable for radiation dose measurement in dental units.
Related Concept Videos
Measurement: Standard Units
Measurement: Derived Units
Biological Effects of Radiation
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...
Units and Standards of Measurement
Measurements of physical quantities are...

