Related Experiment Video
Updated: Jan 25, 2026

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Bubble-Nucleation-Based Method for the Selective and Sensitive Electrochemical Detection of Surfactants
Ruchiranga Ranaweera1, Carina Ghafari2, Long Luo1
1Department of Chemistry , Wayne State University , Detroit , Michigan 48202 , United States.
Abstract:
We present the first bubble-nucleation-based electrochemical method for the selective and sensitive detection of surfactants. Our method takes advantage of the high surface activity of surfactant analyte to affect the electrochemical bubble nucleation and then transduces the change in nucleation condition to electrochemical signal for determining the surfactant concentration. Using this method, we demonstrate the quantitation of perfluorinated surfactants in water, a group of emerging environmental contaminants, with a remarkable limit of detection (LOD) down to 30 μg/L and a linear dynamic range of over 3 orders of magnitude. With the addition of a preconcentration step, we have achieved the LOD: 70 ng/L, the health advisory for perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) in drinking water established by the U.S. Environmental Protection Agency. The experimental results are in quantitative agreement with our theoretical model derived from classical nucleation theory. Our method also exhibits an exceptional specificity for the surfactant analytes even in the presence of 1000-fold excess of nonsurfactant interference. This method has the potential to be further developed into a universal electrochemical detector for surfactant analysis because of its simplicity and the surface-activity-based detection mechanism.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Interfacial Electrochemical Methods: Overview
Excess Pressure Inside a Drop and a Bubble
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
What is Natural Selection?
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

