Related Experiment Video
Updated: Jan 25, 2026

Preparing Adherent Cells for X-ray Fluorescence Imaging by Chemical Fixation
Published on: March 12, 2015
Development of a deep neural network for generating synthetic dual-energy chest x-ray images with single x-ray
Donghoon Lee1, Hwiyoung Kim2, Byungwook Choi2,3
1Department of Radiation Convergence Engineering, Research Institute of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Gangwon, Republic of Korea.
Abstract:
Dual-energy chest radiography (DECR) is a medical imaging technology that can improve diagnostic accuracy. This technique can decompose single-energy chest radiography (SECR) images into separate bone- and soft tissue-only images. This can, however, double the radiation exposure to the patient. To address this limitation, we developed an algorithm for the synthesis of DECR from a SECR through deep learning. To predict high resolution images, we developed a novel deep learning architecture by modifying a conventional U-net to take advantage of the high frequency-dominant information that propagates from the encoding part to the decoding part. In addition, we used the anticorrelated relationship (ACR) of DECR for improving the quality of the predicted images. For training data, 300 pairs of SECR and their corresponding DECR images were used. To test the trained model, 50 DECR images from Yonsei University Severance Hospital and 662 publicly accessible SECRs were used. To evaluate the performance of the proposed method, we compared DECR and predicted images using a structural similarity approach (SSIM). In addition, we quantitatively evaluated image quality calculating the modulation transfer function and coefficient of variation. The proposed model selectively predicted the bone- and soft tissue-only CR images from an SECR image. The strategy for improving the spatial resolution by ACR was effective. Quantitative evaluation showed that the proposed method with ACR showed relatively high SSIM (over 0.85). In addition, predicted images with the proposed ACR model achieved better image quality measures than those of U-net. In conclusion, the proposed method can obtain high-quality bone- and soft tissue-only CR images without the need for additional hardware for double x-ray exposures in clinical practice.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Radiological Investigation I: X-ray and CT
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...

