Related Experiment Video
Updated: Jan 25, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Feasibility study of a new method to measure fast neutron flux by neutron-induced X-ray fluorescence method
Shan Qing1, Zhu Hongkui2, Kong Zhiling2
1Department of Nuclear Science and Engineering, College of Material Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, Jiangsu, People's Republic of China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, 215000, Jiangsu, People's Republic of China.
Abstract:
A new method is proposed to detect fast neutron flux: the neutron-induced X-ray fluorescence method. In this method, the neutrons are firstly converted to charged particles, and then the charged particles interact with the target to generate the characteristic X-ray fluorescence. Finally, the Kα X-ray emission from the target is detected for measurement of the neutron flux. On the basis of this method, the structure of the detection device is designed: it is composed mainly of a layer of a fast neutron converter and a layer of the target. The Geant4 Monte Carlo simulation toolkit is used to optimize the detection device. According to the simulation results, the detection device is manufactured so as to perform the feasibility verification experiments. In the experiments, a D-T neutron generator is used as the neutron source, and the number of neutrons is changed in two ways: by change of the working voltage of the neutron generator or by change of the measurement time. The experimental results show that there is a good linear relationship between the number of neutrons and the Kα X-ray counts when the measurement time is changed. When the working voltage of the neutron generator is changed, a 3He proportional counter is used as a reference detector. The results show that the trend of the Kα X-ray counts is in good agreement with the trend for the 3He proportional counter. It is proved that this method is feasible for fast neutron flux measurement.
Related Concept Videos
Measurement of Bioavailability: Pharmacokinetic Methods
Measurement of Bioavailability: Pharmacodynamic Methods
Microbial Growth Measurement: Direct Methods
Microbial Growth Measurement: Indirect Methods
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:

