Related Experiment Video
Updated: Jan 25, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Simultaneous determination of seven endogenous aldehydes in human blood by headspace gas chromatography-mass
Yi Wei1, Menghan Wang1, Huixia Liu1
1College of Chemistry and Molecular Engineering, Zhengzhou University, PR China.
Abstract:
Endogenous aldehydes (EAs) formed by the free-radical-mediated reaction are regarded as potential biological markers of several diseases. In this work, an automated and solvent-free analytical method was developed for quantitative analysis of seven EAs (C1-C7) in human blood by using gas chromatography-mass spectrometry coupled with a headspace generator sampler (HS-GC-MS). A 1:4 (blood:water) dilution and the 1,2‑dibromopropane internal standard were introduced to reduce the influence of the matrix effect from complex biological fluids. The sample preparation steps were simplified. Various experimental parameters for derivatization and extraction conditions were studied such as HS extraction temperature and time, the amount of derivatization reagent, pH and the salt effect. Under these optimum conditions, seven low-mass aldehydes were separated and analyzed within 10 min. Additionally, this method achieved limits of detection in the range of 0.0692-0.864 μg/L, an excellent linearity with correlation coefficients higher than 0.9996 and appropriate repeatability and reproducibility values (RSD < 12% at low, middle and high levels). The HS-GC-MS method was applied to measure the concentrations of the seven aldehydes in blood from bladder cancer patients (n = 15) and control subjects (n = 15). Compared with the control subjects, the levels of butanal (p < 0.01), formaldehyde, acetaldehyde, propanal, pentanal, hexanal and heptanal (all p < 0.001) were increased significantly, indicating that EAs may be useful as biomarkers in the early diagnosis of bladder cancer.
More Related Videos
04:19Author Spotlight: An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Aldehyde and Ketone Fragmentation
NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II