Related Experiment Video
Updated: Jan 25, 2026

A Novel Surgical Technique in a Sheep Model for Suburethral Graft Implantation
Published on: June 20, 2025
Experimental Studies for Small Diameter Grafts in an In Vivo Sheep Model-Techniques and Pitfalls
Kaveh Eghbalzadeh1, Maria Guschlbauer2, Carolyn Weber1
1Department of Cardiothoracic Surgery, Uniklinik Köln, Köln, Germany.
Background:
Scientific attempts to create the "ideal" small diameter vascular graft have been compared with the "search of the holy grail." Prosthetic material as expanded polytetrafluoroethylene or Dacron shows acceptable patency rates to large caliber vessels, while small diameter (< 6 mm) prosthetic conduits present unacceptably poor patency rates. Vascular tissue engineering represents a promising option to address this problem.
Material And Methods:
Thirty-two female Texel-sheep aged 6 months to 2 years underwent surgical common carotid artery (CCA) interposition using different tissue-engineered vascular substitutes. Explantation of the grafts was performed 12 (n = 12) and 36 (n = 20) weeks after surgery. Ultrasound was performed on postoperative day 1 and thereafter every 4 weeks to evaluate the graft patency.
Results:
The average length of implanted substitutes was 10.3 ± 2.2 cm. Anesthesia and surgical procedure could be performed without major surgical complications in all cases.The grafts showed a systolic blood flow velocity (BFV) of 28.24 ± 13.5 cm/s, a diastolic BFV of 9.25 ± 4.53 cm/s, and a mean BFV of 17.85 ± 9.25 cm/s. Native vessels did not differ relevantly in hemodynamic measurements (systolic: 29.77 cm/s; diastolic: 7.99 cm/s ± 5.35; mean 15.87 ± 10.75). There was no incidence of neurologic complications or subsequent postoperative occlusion. Perioperative morbidity was low and implantation of conduits was generally well tolerated.
Conclusion:
This article aims to give a precise overview of in vivo experiments in sheep for the evaluation of small diameter vascular grafts performing CCA interposition, especially with regard to pitfalls and possible perioperative complications and to discuss advantages and disadvantages of this approach.
Related Concept Videos
Cloning of Dolly the Sheep
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Typical Model Studies
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...
Experimental Determination of Chemical Formula