Related Experiment Video
Updated: Jan 25, 2026

Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling
Published on: October 21, 2018
Two-year data comparison of ab interno trabeculectomy and trabecular bypass stenting using exact matching
Hamed Esfandiari1, Kenneth Taubenslag1, Priyal Shah1
1Department of Ophthalmology, School of Medicine, University of Pittsburgh, Pennsylvania, USA.
Purpose:
To create a balanced comparison of ab interno trabeculectomy (AIT) (Trabectome) and trabecular bypass stenting (TBS) (iStent).
Setting:
Eye and Ear Institute, Pittsburgh, Pennsylvania, Ross Eye Institute, Buffalo, New York, and Glaucoma Associates of Texas, Dallas, USA.
Design:
Retrospective case series.
Methods:
The primary outcome measure was an unmedicated intraocular pressure (IOP) of 21 mm Hg or less and the secondary measure was an unmedicated IOP reduction of 20% or more at 2 years. Patients were matched by baseline IOP, number of glaucoma medications, and glaucoma type using exact matching and by age using nearest neighbor matching. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification.
Results:
One hundred fifty-four AIT eyes and 110 TBS eyes were analyzed. Forty-eight AIT patients were exactly matched with 48 TBS patients. Both groups had a mean baseline IOP of 15.3 mm Hg ± 3.1 (SD). At 24 months, the mean IOP was 13.9 ± 3.3 mm Hg in AIT patients and 16.8 ± 2.8 mm Hg in TBS patients and the mean number of medications was 0.7 ± 1.0 and 1.7 ± 1.2, respectively (both P = .04). At 24 months, the IOP was 21 mm Hg or less without medications in 53% of AIT patients and 16.6% of TBS patients (P < .05). At that time, 17.6% of patients in the AIT group but no patient in the TBS group had an IOP reduction of 20% or more without medication.
Conclusion:
An exact matching comparison of AIT and TBS showed greater IOP reduction with fewer medications after AIT.
More Related Videos
07:59Author Spotlight: Alignment of Synchronized Time-Series Data Using the Characterizing Loss of Cell Cycle Synchrony Model for Cross-Experiment Comparisons
Published on: June 9, 2023
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Fisher's Exact Test
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Wilcoxon Signed-Ranks Test for Matched Pairs
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons