Related Experiment Video
Updated: Jan 25, 2026

Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
Ability of Isokinetic Dynamometer to Predict Isotonic Knee Extension 1-Repetition Maximum
Context:
Resistance training exercise prescription is often based on exercises performed at a percentage of a 1-repetition maximum (1RM). Following knee injury, there is no consensus when a patient can safely perform 1RM testing. Resistance training programs require the use of higher loads, and loads used in knee injury rehabilitation may be too low to elicit gains in strength and power. A maximum isometric contraction can safely be performed during early stages of knee rehabilitation and has potential to predict an isotonic knee extension 1RM.
Objective:
To determine whether a 1RM on an isotonic knee extension machine can be predicted from isometric peak torque measurements.
Design:
Descriptive laboratory study.
Setting:
University research laboratory.
Participants:
A total of 20 (12 males and 8 females) healthy, physically active adults.
Main Outcome Measures:
An isokinetic dynamometer was used to determine isometric peak torque (in N·m). 1RM testing was performed on a knee extension machine. Linear regression was used to develop a prediction equation, and Bland-Altman plots with limits of agreement calculations were used to validate the equation.
Results:
There was a significant correlation (P < .001, r = .926) between peak torque (283.0 [22.6] N·m) and the knee extension 1RM (69.1 [22.6] kg). The prediction equation overestimated the loads (2.3 [9.1] kg; 95% confidence interval, -15.6 to 20.1 kg).
Conclusions:
The results show that isometric peak torque values obtained on an isokinetic dynamometer can be used to estimate 1RM values for isotonic knee extension. Although the prediction equation tends to overestimate loads, the relatively wide confidence intervals indicate that results should be viewed with caution.
More Related Videos
Related Concept Videos
Predicting Products: SN1 vs. SN2
With increased substitution on the alkyl halide,...
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Maximum Power Transfer
By substituting the entire circuit with...
Isotonic and Isometric Muscle Contractions
Isotonic contractions
Isotonic contractions occur when a muscle changes length while...
Maximum Size of Aggregate
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...