Related Experiment Video
Updated: Jan 25, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Randomized Prospective Clinical Trial of Class II Restorations Using Low-shrinkage Flowable Resin Composite
Purpose:
The aim of this prospective, randomized, split-mouth clinical trial was to evaluate postoperative sensitivity, clinical performance, and interproximal contacts after using different restorative systems.
Methods And Materials:
Fifty-three subjects each received three class II restorations according to the restorative systems: conventional resin composite (PA: Peak Universal+Amelogen Plus, Ultradent), low-shrinkage flowable and nanoparticulate resin composites (ABF: Adper Single Bond 2+Filtek Bulk Fill Flow+Filtek Z350XT, 3M ESPE), and low-shrinkage flowable and microhybrid resin composites (XST: XP Bond+SDR+TPH3, Dentsply). Postoperative sensitivity was assessed at 24 hours, seven days, 90 days, and six months. The clinical performance and interproximal contacts were evaluated at baseline, six months, and one year. Friedman, Wilcoxon, Kruskal-Wallis, and Mann-Whitney tests were used to evaluate postoperative sensitivity and interproximal contacts. The equality test of two proportions and logistic regression analysis were used to assess the clinical performance.
Results:
No statistically significant differences were observed among groups for postoperative sensitivity. The highest spontaneous sensitivity was reported at 24 hours. ABF was the only group that did not present a reduction in cold sensitivity. Color, marginal discoloration, and superficial staining showed differences among the groups. XST did not show superficial staining after one year. No differences were observed among groups in relation to interproximal contacts. XST resulted in the loss of interproximal contact after one year.
Conclusions:
Different types of restorative systems do not influence postoperative sensitivity; however, ABF maintained cold sensitivity over time. Marginal discoloration occurred for all groups but occurred earliest for PA. XST presented a reduction of interproximal contact after one year of evaluation.
More Related Videos
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...

