Purpose:
To compare the efficacy of different microinvasive glaucoma surgery (MIGS) devices for reducing intraocular pressure (IOP) and medications in open-angle glaucoma (OAG).
Design:
Prospective, multicenter, randomized clinical trial.
Participants:
One hundred fifty-two eyes from 152 patients aged 45 to 84 years with OAG, Shaffer angle grade III-IV, best-corrected visual acuity (BCVA) 20/30 or better, and IOP 23 to 39 mmHg after washout of all hypotensive medications. Eyes with secondary glaucoma other than pseudoexfoliative or pigmentary glaucoma, angle closure, previous incisional glaucoma surgery, or any significant ocular pathology other than glaucoma were excluded.
Intervention:
Study eyes were randomized 1:1 to standalone MIGS consisting of either 1 Hydrus Microstent (Ivantis, Inc, Irvine, CA) or 2 iStent Trabecular Micro Bypass devices (Glaukos Inc, San Clemente, CA). Follow-up was performed 1 day, 1 week, and 1, 3, 6, and 12 months postoperatively.
Main Outcome Measures:
Within-group and between-group differences in IOP and medications at 12 months and complete surgical success defined as freedom from repeat glaucoma surgery, IOP 18 mmHg or less, and no glaucoma medications. Safety measures included the frequency of surgical complications, changes in visual acuity, slit-lamp findings, and adverse events.
Results:
Study groups were well matched for baseline demographics, glaucoma status, medication use, and baseline IOP. Twelve-month follow-up was completed in 148 of 152 randomized subjects (97.3%). At 12 months, the Hydrus had a greater rate of complete surgical success (P < 0.001) and reduced medication use (difference = -0.6 medications, P = 0.004). More Hydrus subjects were medication free at 12 months (difference = 22.6% P = 0.0057). Secondary glaucoma surgery was performed in 2 eyes in the 2-iStent group (3.9%) and in none of the Hydrus eyes. Two eyes in the Hydrus group and 1 in the 2-iStent group had BCVA loss of ≥2 lines.
Conclusion:
Standalone MIGS in OAG with the Hydrus resulted in a higher surgical success rate and fewer medications compared with the 2-iStent procedure. The 2 MIGS devices have similar safety profiles.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparing the Survival Analysis of Two or More Groups
Comparing Experimental Results: Student's t-Test