Related Experiment Video
Updated: Jan 25, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Extraction and quantitative analysis of water by GC/MS for trace-level dimethylsilanediol (DMSD)
1Toxicology and Environmental Research and Consulting (TERC), Dow Chemical Company, Midland, MI, 48674, USA.
Abstract:
Dimethylsilanediol (DMSD) is related to the most important bifunctional building block for silicone oligomers and polymers, although DMSD itself is not used in any commercial applications. The environmental release of DMSD is linked to the hydrolytic degradation of other silicone materials in soil and water as DMSD is usually one of the major products. Most common extraction and quantification methods are not suitable for the analysis of trace- and ultratrace-levels of DMSD in water. This is because DMSD is highly water soluble and can readily undergo self-condensation when concentrated. In addition, DMSD may also coexist with DMSD precusors such methylsiloxanes in water. In the present study, solid-phase extraction (SPE) in combination with gas chromatography-mass spectrometry (GC/MS) without pre-column derivatization was tested for analyzing water samples for DMSD. It was found that direct analysis by GC/MS can be used for a wide range of concentrations if DMSD was extracted into a dry organic solvent. Isolute® ENV + may be used for such extraction at higher DMSD concentrations, while Supelclean™ ENVI-Carb™ Plus was found to be better for trace and ultratrace analysis. Increased salt content in water can increase its DMSD extraction efficiency, while polarity of the eluting solvents is a determining factor for eluting efficiency. Moisture in the final extract is a detrimental factor for direct GC/MS analysis. With a proper moisture removal procedure and a suitable internal standard, coupling of SPE and direct GC/MS analysis reduces the method detection limits for DMSD to lower ppb levels. Based on field sample analysis, solvent and instrumental background, not instrumental sensitivity, was found to be the limiting factor in lowering the detection limits for this analysis.
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Level and Low-Level Awareness
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Leveling Effect
Levels of Organization
Molecules Are Composed of Atoms, and Biomolecules Are Assembled from Molecules:
The most basic levels include atoms, molecules, and biomolecules. Atoms, the smallest unit of ordinary matter, are composed of a nucleus and electrons. Molecules...

