Related Experiment Video
Updated: Jan 25, 2026

The Use of Drip Flow and Rotating Disk Reactors for Staphylococcus aureus Biofilm Analysis
Published on: December 27, 2010
Operating room PathTrac analysis of current intraoperative Staphylococcus aureus transmission dynamics
Alysha D M Robinson1, Franklin Dexter1, Valerie Renkor1
1Department of Anesthesia, University of Iowa, Iowa City, IA.
Background:
Operating room (OR) reservoir Staphylococcus aureus isolates have been linked to 50% of surgical site infections. We aimed to assess S aureus transmission dynamics in today's ORs to further guide health care-associated infection prevention.
Methods:
Forty OR case-pairs were randomly selected for observation in a 5-month prospective cohort study. Case-pair S aureus transmission dynamics were mapped using OR PathTrac.
Results:
S aureus pathogens were isolated from ≥1 OR reservoirs in 45.7% (37 of 81) of surgical cases, and epidemiologically related transmission events were confirmed in 22.5% (9 of 40) of case-pairs. Patient skin sites and provider hands provided comparable risk of OR S aureus exposure (19 of 481 patient vs 35 of 1,173 provider hands, relative risk [RR], 1.32; 95% confidence interval [CI], 0.77-2.29; P = .32). Environmental contamination at case 2 start was higher than at case 1 start (case 2 start 32 of 152 sites with >20 colony-forming units vs case 1 start 7 of 163 sites with >20 colony-forming units; RR, 4.90; 95% CI, 2.23-10.77; P < .0001). The stopcock contamination rate was not significantly different than our prior study in 2008 (19 of 164 2008 vs 8 of 77 2018; RR, 1.12; 95% CI, 0.51-2.43; P = .78). All epidemiologically related transmission events involved the between-case mode of transmission and phenotype H.
Conclusions:
Current OR S aureus exposure threats reliably include patient skin sites and provider hands. Perioperative S aureus preventive measures should extend from patient decolonization to include improved hand decontamination efforts.
Related Concept Videos
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Design of Transmission Shafts - Stress Analysis
Operational Amplifiers
Electrical Current
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
Operant Conditioning
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...

