In situ measurement of temperature dependent picosecond resolved carrier dynamics in near infrared (NIR) sensitive

Jayita Patwari1, Arka Chatterjee1, Hemant Ghadi2

  • 1Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700 106, India.

Related Concept Videos

Temperature Dependence on Reaction Rate02:55

Temperature Dependence on Reaction Rate

The Collision Theory
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
88.7K
Temperature Dependent Deformation01:12

Temperature Dependent Deformation

In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added...
377
Electron Carriers01:24

Electron Carriers

Electron carriers can be thought of as electron shuttles. These compounds can easily accept electrons (i.e., be reduced) or lose them (i.e., be oxidized). They play an essential role in energy production because cellular respiration is contingent on the flow of electrons.
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
91.5K
Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
3.3K
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.8K
Carrier Transport01:21

Carrier Transport

The generation of electrical current in semiconductors is fundamentally driven by two mechanisms: drift and diffusion. These processes are essential for the functionality and performance of semiconductor-based devices.
Drift Current:
The drift of charge carriers is started by an external electric field (E). Charged particles, such as electrons and holes, experience an acceleration between collisions with lattice atoms. For electrons, this results in a drift velocity (vd) given by:
929