Related Experiment Video
Updated: Jan 25, 2026

Robotic Enucleation of an Intra-Pancreatic Insulinoma in the Pancreatic Head
Published on: January 3, 2020
Endosonographer-driven dynamic telecytopathology of pancreatic lesions-a pilot study
Benjamin Tharian1, Konrad Krall2, Xiang Zhu2
1Center for Interventional Endoscopy (CIE), Florida Hospital, Orlando, Florida; University of Arkansas for Medical Sciences (UAMS), Little Rock, Arkansas.
Introduction:
Telecytopathology for endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has been shown to be an alternative to rapid on-site evaluation (ROSE). Gastroenterologists (endosonographers) performing EUS-FNA can be trained to evaluate a specimen for adequacy. This study examined the ability of an endosonographer with focused cytopathologic training to assess the adequacy of pancreatic FNA specimens and transmit diagnostic images to a remotely located cytopathologist as compared to an experienced cytotechnologist.
Materials And Methods:
This was a retrospective study of consecutive pancreatic lesions sampled by EUS-FNA reviewed by an endosonographer and a cytotechnologist. The participants were assessed based on their ability to (1) determine adequacy, (2) locate and transmit representative cell groups, (3) provide a preliminary diagnosis, and (4) provide concordance with actual diagnosis.
Results:
105 consecutive cases of EUS-FNA of the pancreas were analyzed, including: adenocarcinoma (n = 39), cyst (n = 17), neuroendocrine neoplasia (n = 7), pancreatitis (n = 14), benign pancreas (n = 9), other neoplasms (n = 6), suspicious/atypical (n = 3), and nondiagnostic (n = 10). The cytotechnologist demonstrated superiority in accuracy 92.7% versus 70% (P = 0.003) and subcategorization 95.0% versus 76% (P = 0.007). There was no difference in "broad" categorization (benign/malignant) between the endosonographer and cytotechnologist, 98% and 98.2% (P = 0.946), respectively. Also, there was no difference with regard to adequacy assessment (P = 0.29). A steady learning curve for the endosonographer was demonstrated in their cytologic assessment (P = 0.041). The endosonographer was shown to be able to remotely transmit diagnostic images to a pathologist.
Conclusion:
An endosonographer with limited training can examine for specimen adequacy, transmit images, and demonstrate representative cell groups. Larger studies are required though preliminary results are encouraging.
More Related Videos
03:34Laparoscopic Duodenum-Preserving Pancreatic Head Resection via Inferior Infracolic Approach: A Surgical Approach for Benign Lesions
Published on: February 9, 2024
09:10Reconstituting and Characterizing Actin-Microtubule Composites with Tunable Motor-Driven Dynamics and Mechanics
Published on: August 25, 2022
Related Concept Videos
Pilot and Numeric Relaying
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Dynamic Equilibrium
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Xylem and Transpiration-driven Transport of Resources
Pancreatic Juice and Secretion
When acidic chyme from the stomach enters the duodenum, it triggers the release of secretin, a hormone that prompts pancreatic juice secretion. After a fatty meal, cholecystokinin, another hormone, stimulates gallbladder contraction and enhances enzyme-rich...