Fixation Location and Stability Using the MP-1 Microperimeter in Stargardt Disease: ProgStar Report No. 3
Etienne M Schönbach1, Mohamed A Ibrahim1, Rupert W Strauss2
1Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland.
Purpose:
To determine fixation location and fixation stability in Stargardt disease (STGD1) and their association with best-corrected visual acuity (BCVA).
Design:
Cross-sectional analysis within the multicenter, prospective ProgStar study.
Participants:
A total of 238 patients and 440 eyes with ABCA4-related STGD1.
Methods:
Patients underwent testing with the Nidek MP-1 microperimeter (Nidek Technologies Inc., Gamagōri, Japan). Fixation location was expressed as the eccentricity of the preferred retinal locus (PRL) from the anatomic fovea, fixation stability was expressed as the bivariate contour ellipse area (BCEA), and BCVA was expressed as Early Treatment Diabetic Retinopathy Study (ETDRS) letters. Linear models with generalized estimating equations were used for statistical analysis while accounting for between-eye correlations.
Main Outcome Measures:
Fixation location and fixation stability.
Results:
Median PRL eccentricity from the fovea was 6° (mean, 6.3°; range, 0°-25°) and median BCEA was 6.31°2 (mean, 12.31°2; range, 0.03°2-365.63°2). Each year of later onset of symptoms of STGD1 was associated with 0.14° more central fixation location (P < 0.0001), but not with fixation stability (P = 0.53). A single linear model best described the relationship between fixation location and BCVA: 1° farther PRL eccentricity was associated with a 2.3-letter loss of BCVA (P < 0.0001). A piecewise linear model best described the relationship between fixation stability and BCVA: for a BCEA less than 2.8°2, an increase in BCEA by 1°2 was associated with a 10.5-letter (ETDRS) lower BCVA (P < 0.0001). For a BCEA 2.8°2 or more, an increase in BCEA by 1°2 was associated with a 0.036-letter (ETDRS) lower BCVA (P = 0.0234). Pearson correlation coefficients between patients' right and left eyes were 0.89 (P < 0.0001) for fixation location and 0.25 (P = 0.0006) for fixation stability. After 10 years of disease duration, 82% of patients had eccentric PRLs in both eyes.
Conclusions:
We provide the first extensive database of continuous fixation parameters in STGD1 and demonstrate their association with vision. These measures allow for a more comprehensive assessment of retinal function and may serve as potential secondary outcome measures for future treatment trials for STGD1 and other macular diseases.
More Related Videos
Related Concept Videos
Nuclear Stability
To hold positively charged protons together...
RNA Stability
mRNA Stability and Gene Expression
Cis-acting Elements involved in mRNA stability
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Location and Orientation of the Heart
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...