Measurement of Carotenoids in Perifovea using the Macular Pigment Reflectometer
Published on: January 29, 2020
Stargardt Macular Dystrophy: Changes in Fixation When Asked to Look Straight Ahead
Mary Lou Jackson1, William Seiple2
1Vancouver General Hospital/University of British Columbia Eye Care Center, Vancouver, Canada.
Purpose:
To examine whether individuals with Stargardt disease macular dystrophy (STGD) change the location of fixation with instruction.
Design:
Case-control study.
Participants:
Thirteen normally sighted and 37 STGD participants.
Methods:
Using an Optos scanning laser ophthalmoscopy/OCT microperimeter (Optos plc, Dunfermline, UK), fixation was measured under 2 different instructions: "look at the cross" (LC) and "look straight ahead, even if you do not see the cross" (LS). Visual acuity, contrast sensitivity, disease duration, and age at disease onset were obtained from medical records.
Main Outcome Measure:
Change in fixation with instruction.
Results:
Mean age of the STGD participants was 39.2 years, and 24 were women. Mean acuity was 1.01±0.29 logarithm of the minimum angle of resolution (logMAR), and mean contrast sensitivity was 1.16±0.41 log. The largest number of fixations under the LC condition were in the superior retina. Patients with STGD were divided into 3 groups, depending on the change in fixation locus when asked to look straight ahead: those having fixation closer the fovea, those with no change in the location of fixation, and those looking farther away from the fovea. Fifty-one eyes of 32 participants had fixations closer to the fovea when asked to look straight ahead (average change, -6.3°), whereas 13 eyes of 11 participants did not change fixation. There were no significant differences between groups in age, visual acuity, contrast sensitivity, bivariate contour ellipse area, and age at disease onset.
Conclusions:
Despite having eccentric fixation, most STGD participants did not have a complete directional re-referencing from the fovea to the eccentric location, and moved fixation when asked to look straight ahead. This finding emphasizes that reliable assessment of visual function during evaluations of disease progression or in therapeutic intervention trials requires consistent instructions and monitoring of fixation. Otherwise, a patient's interpretation of fixation instruction may confound the results.
More Related Videos
Related Concept Videos
Generation of Straight or Branched Actin Filaments
Arp2/3 Complex
Arp2/3 complex is a seven-subunit complex consisting of two proteins similar to actin- Arp2 and Arp3, and five other subunits that help keep Arp2 and Arp3 inactive. When required, the complex is...
Magnetic Field Due To A Thin Straight Wire
Magnetic Field Due to Two Straight Wires
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Satellite Stem Cells and Muscular Dystrophy
Carbon-dioxide Fixation