Related Experiment Video
Updated: Jan 25, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Automatic peak detection coupled with multivariate curve resolution-alternating least squares for peak resolution in
Yue-Ming Zhang1, Yu-Ying Zhang1, Qian Zhang1
1College of Pharmacy, Ningxia Medical University, Yinchuan 750004, China; Ningxia Engineering and Technology Research Center for Modernization of Hui Medicine, Ningxia Medical University, Yinchuan 750004, China.
Abstract:
Gas chromatography-mass spectrometry (GCMS) has been extensively used in complex sample analysis for the high-throughput characterization of volatile and semivolatile compounds. However, the accurate extraction of compound information remains challenging. Here, we present a combined algorithm strategy for GCMS data analysis to accurately screen metabolites across groups. First, chromatographic peaks in a total ion chromatogram (TIC) are extracted by using a Gaussian smoothing strategy and aligned on the basis of their mass spectra by a dynamic programing algorithm. The aligned TIC peaks are then registered into a component list table by applying a nearest-neighbor clustering algorithm. Significantly expressed TIC peaks among groups are screened through statistical analysis, such as ANOVA. Second, a chemometric method of multivariate curve resolution-alternating least squares for the peak resolution of the screened TIC peaks is utilized to retrieve the chromatographic and mass spectral profiles of coeluted components. The developed strategy is employed for the analysis of standard and complex plant sample datasets. Results indicate that our methodology is comparable with several state-of-the-art methods that are widely used in GC-MS-based metabolomics.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Resolution Mass Spectrometry (HRMS)
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
IR Spectrum Peak Broadening: Hydrogen Bonding
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular...
IR Spectrum Peak Intensity: Dipole Moment