Related Experiment Video
Updated: Jan 25, 2026

Author Spotlight: Development of an Enhanced Protocol for Rapid and Accurate Isolation of Campylobacter from Food Products
Published on: February 23, 2024
Comparison of Methods for Isolation of Listeria from Raw Milk
A M Lund1, E A Zottola1, D J Pusch1
1Minnesota-South Dakota Dairy Foods Research Center, Department of Food Science and Nutrition, University of Minnesota, St. Paul, Minnesota 55108.
Abstract:
Methods used to isolate Listeria spp. from raw milk were compared during a 13-month period (April 1989-April 1990). Raw milk was obtained bimonthly from 12 dairy farms during this time period. Three enrichments were compared: Listeria enrichment broth (LEB); University of Vermont medium (UVM), followed by a secondary enrichment with Fraser broth; and LPALCAMY. Four selective plating media, including Listeria selective agar-Oxford formulation; Modified McBride Listeria agar (MMLA); Lithium chloride-phenylethanol-moxalactam (LPM) agar; and L-PALCAM agar, were compared. L-PALCAMY enrichment broth enhanced isolation of L. monocytogenes and other Listeria spp. The greatest numbers of positive Listeria samples were obtained on Oxford and PALCAM agars, while the poorest isolation was obtained using the combination of LEB with MMLA. L. monocytogenes was found to be present in 3.0% (9/300) of the samples analyzed. The incidence of Listeria spp. was 28.0%; Listeria innocua , 26.7%; and Listeria welshimeri , 1.7%. Listeria ivanovii was not isolated. The incidence of Listeria was highest during the warmer months of April-July, while the lowest incidences occurred in December and February. Somatic cell counts (SCC) and standard plate counts (SPC) were determined by the cooperative that supplied the raw milk. In general, a producer's milk with high SPC corresponded to a high incidence of Listeria spp., while low SPC corresponded to a low incidence. A particular producer's milk with the highest incidence of Listeria spp. also had the highest SCC.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits

