A Model for Consistency Analysis of Radiological CRT Monitors
Mark F Mc Entee1, Cherrie Wade1, Patrick C Brennan2
1University College Dublin, Diagnostic Imaging, School of Medicine and Medical Science, Health Sciences Centre, Belfield, Dublin, Ireland.
Abstract:
This study examines the performance of a selection (n = 33) of cathode ray tube monitors used in radiology. Previously published quality assurance tests and standards are used and evaluated and the data provided were used to determine the utility of each test. Recommendations for a program of consistency analysis suitable for imaging departments using cathode ray tube devices are made. The tests included in this study are: examination of the ambient viewing environment; calibration of the monitor to the Digital Imaging and Communications in Medicine Grayscale Standard Display Function; and assessment of image quality using a selection of American Association of Physicists in Medicine Task Group 18 (TG18) test patterns. Cathode ray tube monitor performance was seen to vary across departments and nonadherence to international standards for specific parameters was noted. On the basis of the results, a program for consistency analysis was recommended. Ambient light levels should be assessed using a photometer. Calibration of workstation monitors should be completed on a quarterly basis. Comprehensive image quality analysis using the TG18-Quality Control test pattern that facilitates the investigation of a number of quality parameters must be assessed at parameter-specific intervals. This should be supplemented with the TG18-Glare Visual test pattern for an assessment of veiling glare. Implementation of the recommendations above should enhance diagnostic efficacy and subsequent patient management.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Therapeutic Drug Monitoring: Drug Analysis Methods
Self-Presentation: Self-Monitoring and Self-Handicapping
Holter Monitor: 24-Hour Monitoring