100 μA-100 kV Photon-counting X-ray Computed Tomography System Using an LSO-MPPC Detector and a High-Speed Comparator
Tomoko Maeda1, Eiichi Sato1, Ryo Matsushita1
1Department of Physics, Iwate Medical University, Yahaba, Iwate, Japan.
Abstract:
A high-sensitive x-ray computed tomography (CT) system is useful for decreasing absorbed dose for patients, and we performed preliminary experiments for first-generation photon-counting CT using a high-sensitive single detector. X-ray photons are detected using an LSO [Lu2(SiO4)O] single crystal scintillator and a multipixel photon counter (MPPC). The photocurrent from the MPPC is amplified by a current-voltage amplifier and an integrator, and the event pulse is sent to a high-speed comparator. Logical pulses are then produced by the comparator and are counted by a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The count rate decreased with increase in lower level voltage of the comparator Vl, and the maximum count rate was 265 kcps at a Vl of 0.4 V. The exposure time for obtaining a tomogram was 10 minutes at a scan step of 0.5 mm and a rotation step of 1.0°. The image contrast of gadolinium medium slightly varied with change in Vl. We carried out low-dose-rate photon-counting CT at a tube current of 100 μA and a tube voltage of 100 kV. The energy-dispersive effect of the CT image was confirmed by selecting Vl. The absorbed dose for objects can be reduced using the linear detector consisting of plural LSO-MPPC detectors.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...