Introduction:
The aim of this study was to assess the influence of background activity on the accuracy of volume estimation of target objects using an iterative thresholding method.
Methods:
Single-photon-emission computed tomography studies were carried out for plastic bottles of various sizes as target objects containing Technetium-99m placed in a cylindrical water phantom. The phantoms were created to have varying ratios of target activity concentration to background activity concentration (T/B) ranging from 4.00 to 1.25. From the single-photon-emission computed tomography slices, the volume of the target object was estimated using an iterative thresholding method. A unique threshold that estimated the volume of the target object was determined and declared as ideal threshold for each level of background activity. Simple linear regression analysis was carried out to explore the relationship between the actual volume and estimated volume.
Results:
The analysis shows a statistically significant linear relationship (P < .01) between actual volume and estimated volume. For all ratios of target activity concentration to background activity concentration studied, the relative errors in estimated volumes of target objects are within ±7%. Thresholds that estimated volume of target objects vary depending on the level of background activity.
Conclusions:
It is clearly demonstrated that background activity highly influenced the volume estimation. Therefore, background activity of the target object needs to be considered when selecting the ideal thresholds to obtain accurate volume estimation of target objects.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Emission Spectra
Area Computation by the Alternative Coordinate Method