Yttrium Residues in MWCNT Enable Assessment of MWCNT Removal during Wastewater Treatment
Justin Kidd1, Yuqiang Bi2, David Hanigan3
1Nanosystems Engineering Research Center for Nanotechnology Enabled Water Treatment, School of Sustainable Engineering and The Built Environment, Arizona State University, Tempe, AZ 85287-3005, USA. justin.kidd@asu.edu.
Abstract:
Many analytical techniques have limited sensitivity to quantify multi-walled carbon nanotubes (MWCNTs) at environmentally relevant exposure concentrations in wastewaters. We found that trace metals (e.g., Y, Co, Fe) used in MWCNT synthesis correlated with MWCNT concentrations. Because of low background yttrium (Y) concentrations in wastewater, Y was used to track MWCNT removal by wastewater biomass. Transmission electron microscopy (TEM) imaging and dissolution studies indicated that the residual trace metals were strongly embedded within the MWCNTs. For our specific MWCNT, Y concentration in MWCNTs was 76 µg g-1, and single particle mode inductively coupled plasma mass spectrometry (spICP-MS) was shown viable to detect Y-associated MWCNTs. The detection limit of the specific MWCNTs was 0.82 µg L-1 using Y as a surrogate, compared with >100 µg L-1 for other techniques applied for MWCNT quantification in wastewater biomass. MWCNT removal at wastewater treatment plants (WWTPs) was assessed by dosing MWCNTs (100 µg L-1) in water containing a range of biomass concentrations obtained from wastewater return activated sludge (RAS) collected from a local WWTP. Using high volume to surface area reactors (to limit artifacts of MWCNT loss due to adsorption to vessel walls) and adding 5 g L-1 of total suspended solids (TSS) of RAS (3-h mixing) reduced the MWCNT concentrations from 100 µg L-1 to 2 µg L-1. The results provide an environmentally relevant insight into the fate of MWCNTs across their end of life cycle and aid in regulatory permits that require estimates of engineered nanomaterial removal at WWTPs upon accidental release into sewers from manufacturing facilities.
Related Concept Videos
Residual Stresses
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Residual Stresses in Circular Shafts
Residual Stresses in Bending
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration


