Related Experiment Video
Updated: Jan 25, 2026

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Dynamic phase extraction in high-SNR DAS based on UWFBGs without phase unwrapping using scalable homodyne
Abstract:
We demonstrate a Distributed Acoustic Sensor (DAS) based on Ultra-Weak Fiber Bragg Gratings (UWFBGs) using a scalable homodyne demodulation in direct detection. We show that a distributed interferometric system using delay and mixing of backscattering from consecutive identical gratings can be combined with a Phase-Generated Carrier Differentiate and Cross-Multiply (PGC-DCM) demodulation algorithm to perform dynamic measurements with high SNR, employing a simple narrowband laser and a pin photodiode. The proposed homodyne demodulation technique is suitable for real-time monitoring using distributed measurements, as it does not require computationally costly phase unwrapping common in conventional schemes and is robust against detrimental harmonic distortions, while not requiring additional mechanisms to handle division-by-zero operations. The demodulation scheme is also scalable, as it involves symmetric ordinary differentiation and integration operations suitable for processing with FPGA-based or analogue systems which, thanks to readily realizable schemes for implementing fractional order calculus, are also candidates for small-scale integration. We experimentally demonstrate the effectiveness of the technique by monitoring the dynamic response of a generic 2.5 kHz vibration applied to a PZT placed at the end of a sensing fiber comprised of a 1 km array of 200 UWFBGs each with a reflectivity of ~-43 dB written at a spacing of 5 m, with an SNR of ~34.52 dB.
Related Concept Videos
Phase Transitions
Phase Diagrams
Phase Transitions: Sublimation and Deposition
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...

