Evaluation of ventriculo-arterial coupling in ST elevation myocardial infarction with left ventricular dysfunction
Paolo Trambaiolo1, Pietro Bertini2, Nunzia Borrelli3
1ICCU, Sandro Pertini Hospital, Roma, Italy.
Background:
Acute heart failure (AHF) after ST-segment elevation myocardial infarction (STEMI) is usually treated with inotropic support or vasoactive medications. In this study, we aimed at investigating the role of levosimendan on cardiovascular determinants of contractility and afterload in patients with AHF following STEMI treated with percutaneous coronary intervention (PCI).
Methods:
Forty-eight consecutive STEMI patients were retrospectively enrolled. Non-invasive assessment of left ventricular elastance (Ees) and arterial elastance (Ea) and their relationship, ventriculo-arterial coupling (VAC) was performed before and after levosimendan infusion.
Results:
After infusion of levosimendan a significant increase in SV was detected in all patients (from 48 ± 17 to 60 ± 21 ml, p < 0.001). VAC slightly decreased from 1.74 ± 0.8 to 1.66 ± 0.7 (p = NS) as a result of a profound reduction in arterial elastance (Ea 2.34 ± 1.09 to 1.74 ± 0.5 mm Hg/ml, p < 0.001) and in ventricular elastance (Ees 1.57 ± 0.12 to 1.24 ± 0.09 mm Hg/ml, p = 0.021). Ejection fraction (EF) (from 0.29 ± 0.1 to 0.32 ± 0.1, p < 0.01) and WMSI, (from 2.16 ± 0.47 to 2.05 ± 0.54, p < 0.05) also, significantly improved. Finally, baseline VAC was able to predict the use of norepinephrine (NE) and early and one-year mortality of patients treated.
Conclusion:
In STEMI patients with AHF the use of levosimendan significantly increases stroke volume after 24-hour treatment through Ea reduction. Baseline VAC seemed to predict early and late mortality and early and prolonged use of NE, however, this needs to be tested in larger series of patients and multivariate adjustments for other prognostic predictors.
Related Concept Videos
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Elevation of Intermediate Points on Vertical Curves
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
G-protein Coupled Receptors