Influence of Light-curing Units on Surface Microhardness and Color Change of Composite Resins after Challenge
Morganna B de A Souza1, André Lf Briso1, Bruna de Oliveira-Reis1
1Department of Restorative Dentistry, UNESP - São Paulo State University, Araçatuba School of Dentistry, Araçatuba, SP, Federative Republic of Brazil.
Aim:
The aim of this study was to evaluate microhardness and color change (ΔE) of composite resins, light cured with different light emission diodes (LEDs) and submitted to artificial accelerated aging (AAA).
Materials And Methods:
Two composite resins with lucirin- TPO photoinitiator were selected: Tetric N-Ceram (Ivoclar Vivadent, A1) and Vit-l-escence (Ultradent, WO).A resin with the only camphorquinone photoinitiat or was chosen as a negative control: Filtek Z350XT (3M ESPE, WD). Disc-shaped specimens were prepared (5 mm diameter; 1.5 mm thick) and photopolymerized with an LED with one wavelength (Radii-Cal, SDI) or multiple wavelengths (Valo, Ultradent), for each composite resin (n = 10). Surface microhardness and color evaluations were performed immediately after specimen preparation and after AAA. Microhardness results were analyzed using Kruskal-Wallis and Mann-Whitney tests for multiple comparisons. To compare the evaluation of microhardness at different times, the Wilcoxon test was used. Mean values of ΔE, ΔL, Δa, and Δb were evaluated using two-way analysis of variance (ANOVA), and Tukey test for multiple comparisons (a = 0.05).
Results:
Regarding microhardness, a statistically significant difference between the two LEDs was observed for Vit-lescence after AAA. When comparing composite resins that were light-cured with the same device, FiltekZ350XT obtained the greatest microhardness. All groups presented a statistically significant decrease in microhardness from the initial time to the AAA. Regarding ΔE, no statistically significant difference between the two LEDs was observed. When comparing composite resins, FiltekZ350XT showed the highest ΔE values.
Conclusion:
In general, an LED with multiple wavelengths influenced the microhardness of only one resin containing lucirin-TPO after AAA. The ΔE was more influenced by the composite resin than the LED device.
Clinical Significance:
The knowledge of composite resin with deficiencies in the polymerization mechanism could contribute to preventing restorations to become more susceptible to color change and reduction of the mechanical strength.
More Related Videos
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
06:26Experimental Implementation of a New Composite Fabrication Method: Exposing Bare Fibers on the Composite Surface by the Soft Layer Method
Published on: October 6, 2017
Related Concept Videos
Curing of Concrete
Curing Methods
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Accelerated Curing of Concrete
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Measurement: Derived Units