Related Experiment Video
Updated: Jan 25, 2026

Helical Organization of Blood Coagulation Factor VIII on Lipid Nanotubes
Published on: June 3, 2014
Effects and Interferences of Emicizumab, a Humanised Bispecific Antibody Mimicking Activated Factor VIII Cofactor
Joanne I Adamkewicz1, David C Chen1, Ido Paz-Priel1
1Genentech, Inc., South San Francisco, California, United States.
Emicizumab bridges activated factor IX (FIX) and FX to restore the tenase function mediated by activated FVIII (FVIIIa), which is deficient in people with haemophilia A (PwHA). Unlike FVIII, emicizumab does not require activation to function; thus, in coagulation assays, the behavior of emicizumab may differ from that of FVIII. The objective of this study was to assess the effect of emicizumab on coagulation assays, including potential interference behavior that may produce inaccurate or misleading results. A variety of clotting-based, amidolytic/chromogenic, latex particle-enhanced turbidometric, and enzyme-linked immunosorbent methods were investigated. As expected based on its pharmacologic mechanism of action, emicizumab exhibited strong activity on the activated partial thromboplastin time (aPTT), which resulted in interference with several aPTT-based assays, most importantly the one-stage FVIII activity assay; these assays are not recommended for PwHA receiving emicizumab therapy. Pharmacodynamic activity of emicizumab, as measured by FVIII chromogenic assays, was species-dependent due to the binding specificity of the drug antibody. Outside of FVIII assays, emicizumab did not interfere with assays based on immunologic or chromogenic principles, nor with clotting assays based on nonintrinsic pathway activators, thus offering alternative choices where aPTT-based assays might otherwise be used. The observed interferences are in line with the unique mechanism of action of emicizumab. Potential interferences should be taken into account in the selection of coagulation assays and interpretation of coagulation assay test results for PwHA receiving emicizumab therapy.
Emicizumab bridges activated factor IX (FIX) and FX to restore the tenase function mediated by activated FVIII (FVIIIa), which is deficient in people with haemophilia A (PwHA). Unlike FVIII, emicizumab does not require activation to function; thus, in coagulation assays, the behavior of emicizumab may differ from that of FVIII. The objective of this study was to assess the effect of emicizumab on coagulation assays, including potential interference behavior that may produce inaccurate or misleading results. A variety of clotting-based, amidolytic/chromogenic, latex particle-enhanced turbidometric, and enzyme-linked immunosorbent methods were investigated. As expected based on its pharmacologic mechanism of action, emicizumab exhibited strong activity on the activated partial thromboplastin time (aPTT), which resulted in interference with several aPTT-based assays, most importantly the one-stage FVIII activity assay; these assays are not recommended for PwHA receiving emicizumab therapy. Pharmacodynamic activity of emicizumab, as measured by FVIII chromogenic assays, was species-dependent due to the binding specificity of the drug antibody. Outside of FVIII assays, emicizumab did not interfere with assays based on immunologic or chromogenic principles, nor with clotting assays based on nonintrinsic pathway activators, thus offering alternative choices where aPTT-based assays might otherwise be used. The observed interferences are in line with the unique mechanism of action of emicizumab. Potential interferences should be taken into account in the selection of coagulation assays and interpretation of coagulation assay test results for PwHA receiving emicizumab therapy.
Related Concept Videos
Cofactors and Coenzymes
Cofactors and Coenzymes
Cofactors can be metallic ions or organic molecules called coenzymes. These types of helper...
Coagulation
Coagulation
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
Interference and Diffraction

