Rim-to-Disc Ratio Outperforms Cup-to-Disc Ratio for Glaucoma Prescreening
J R Harish Kumar1,2, Chandra Sekhar Seelamantula3, Yogish Subraya Kamath4
1Department of Electrical Engineering, Indian Institute of Science, Bangalore, 560012, India. harishj@iisc.ac.in.
This study introduces an automated glaucoma screening method using the rim-to-disc ratio (RDR) from fundus images. The novel technique accurately assesses glaucoma severity, outperforming traditional cup-to-disc ratio (CDR) methods.
Area of Science:
- Ophthalmology
- Medical Imaging
- Computer Vision
Background:
- Glaucoma is a leading cause of irreversible blindness worldwide.
- Accurate and early detection of glaucoma is crucial for preventing vision loss.
- Current diagnostic methods often rely on manual interpretation of fundus images, which can be subjective and time-consuming.
Purpose of the Study:
- To develop and validate a novel, fully automated fundus image processing technique for glaucoma prescreening.
- To assess glaucoma severity using the rim-to-disc ratio (RDR) and the disc-damage-likelihood scale (DDLS).
- To compare the performance of the RDR-based method against the traditional cup-to-disc ratio (CDR) system.
Main Methods:
- Automated segmentation of the optic disc and optic cup in fundus images.
- Calculation of the rim-to-disc ratio (RDR) using an active disc model optimized for local contrast.
- Classification of images into normal, moderate, or severe glaucoma categories based on RDR and DDLS.
- Validation using public databases and manufacturer data, with performance assessed against expert annotations.
Main Results:
- The automated RDR-based technique achieved high accuracy in segmenting optic discs and cups.
- The RDR-based glaucoma assessment demonstrated 8% to 10% greater accuracy than CDR-based systems.
- Ablation studies confirmed RDR's superiority over CDR in both two-stage and three-stage glaucoma classification.
Conclusions:
- The developed automated RDR and DDLS technique offers a reliable and efficient approach for glaucoma prescreening and severity assessment.
- This novel engineering approach provides a significant improvement over existing CDR-based methods.
- The findings suggest potential for widespread clinical adoption to enhance early glaucoma detection and management.