Effects of high PEEP and fluid administration on systemic circulation, pulmonary microcirculation, and alveoli in a
Huaiwu He1, Qinhe Hu1,2, Yun Long1
1Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China.
Abstract:
This study aimed to determine the response of systemic circulation, pulmonary microcirculation, and alveoli to high positive end-expiratory pressure (PEEP) in a canine model. This study was conducted in nine mixed-breed dogs on mechanical ventilation under anesthesia. The PEEP was initially set at 5 cmH2O (PEEP5), the PEEP was then increased to 25 cmH2O (PEEP25), and then saline was used for fluid loading. Data were obtained at the following time points: PEEP5; PEEP25 prefluid loading; and PEEP25 postfluid loading. The images of subpleural lung microcirculation were assessed by sidestream dark-field microscopy, and the hemodynamic data were collected from pulse contour waveform-derived measurements. Compared with PEEP5, the lung microvascular flow index (MFI, 2.3 ± 0.8 versus 0.9 ± 0.8, P = 0.001), lung perfused vessel density (PVD, 4.2 ± 2 versus 1.5 ± 1.8, P = 0.004), lung proportion of perfused vessel (PPV, 93 ± 14 versus 40 ± 4, P = 0.003), cardiac output (2.5 ± 0.6 versus 1.4 ± 0.5, P = 0.001), and mean blood pressure (116 ± 24 versus 91 ± 31, P = 0.012) were significantly lower at PEEP25 prefluid loading. After fluid loading, there were no significant differences in cardiac output or mean arterial pressure between the PEEP5 and PEEP25 postfluid loading levels. However, the lung microcirculatory MFI, PVD, and PPV at PEEP25 postfluid loading remain lower than at PEEP5. A significant increase in septal thickness was found at PEEP25 postfluid loading relative to septal thickness at PEEP25 prefluid loading (25.98 ± 5.31 versus 40.76 ± 7.9, P = 0.001). Under high PEEP, systemic circulation was restored after fluid loading, but lung microcirculation was not. Moreover, the septal thickness of alveoli significantly increased after fluid loading.NEW & NOTEWORTHY An excessively high positive end-expiratory pressure (PEEP) can impair the systemic circulation and alveolar microcirculation. In the high-PEEP condition, fluid loading restored the systemic circulation but did not affect the impaired lung microcirculation. The septal thickness of the alveoli significantly increased after fluid loading in the high-PEEP condition.
More Related Videos
09:28Intravital Widefield Fluorescence Microscopy of Pulmonary Microcirculation in Experimental Acute Lung Injury Using a Vacuum-Stabilized Imaging System
Published on: April 6, 2022
11:20A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Related Concept Videos
Overview of Systemic and Pulmonary Circulation
The oxygenated blood is sent...
Overview of Pulmonary Circulation
The process begins with the right ventricle of the heart pumping deoxygenated blood into the pulmonary trunk. This large vessel extends about 5 centimeters before splitting into the left and right pulmonary arteries. These arteries...
The Fluid Mosaic Model
Alveoli and Alveolar Ducts
Fluid Mosaic Model
Two-Compartment Open Model: Extravascular Administration
The absorption exponent (ka) indicates the speed at which the drug...