Detection of left atrial appendage thrombi by third-generation dual-source dual-energy CT: Iodine concentration
Wenhuan Li1, Fangfang Yu1, Weiwei Zhu2
1Department of Radiology, Beijing Chao-Yang Hospital, Capital Medical University, China.
Background:
Dual-energy computed tomography (DECT) can differentiate iodine from other materials through the material decomposition technique. The purpose of this study was to compare the diagnostic performance of DECT-derived iodine concentration (mg/ml) with conventional enhancement measurements (HU), in detecting left atrial appendage (LAA) thrombi and differentiating thrombi from circulatory stasis in atrial fibrillation (AF) patients referred for catheter ablation.
Methods:
Consecutive patients were prospectively recruited and scanned using a third-generation dual-source CT system in dual-energy mode. Regions of interest were placed inside the filling defect in the LAA and ascending aorta (AA) of the same sections, to determine iodine concentration and the LAA/AA HU ratio. The diagnostic performance of iodine concentration and LAA/AA HU ratios were compared using transesophageal echocardiography (TEE) as the reference standard.
Results:
Among 302 patients, 10 thrombi and 27 cases with spontaneous echo contrast (SEC) were detected by TEE. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of iodine concentration were superior to those of LAA/AA HU ratios (iodine concentration: 99.7%, 100%, 99.7%, 90.9%, and 100% vs. LAA/AA HU ratios: 96.0%, 100%, 95.9%, 45.5%, and 100%) in detecting LAA thrombi. The area under the receiver operating characteristic curve of iodine concentration (0.996; 0.898-1.000) was significantly larger than that of the LAA/AA HU ratio (0.881; 0.733-0.964) in differentiating thrombi from circulatory stasis (p < 0.05).
Conclusions:
DECT-derived iodine concentration was associated with improved diagnostic accuracy compared with conventional enhancement measurements in detecting LAA thrombi and differentiating thrombi from circulatory stasis in AF patients.
More Related Videos
Related Concept Videos
Dual Nature of Electromagnetic (EM) Radiation
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
Drug Concentrations: Measurements
Plasma...
Surface Appendages of Archaea
Free Energy
Concentration Cells
Consider the following voltaic cell:
Activation Energy