Related Experiment Video
Updated: Jan 25, 2026

Deep Learning-Based Segmentation of Cryo-Electron Tomograms
Published on: November 11, 2022
Assessment of Critical Feeding Tube Malpositions on Radiographs Using Deep Learning
Varun Singh1,2, Varun Danda3, Richard Gorniak3
1Department of Radiology, Thomas Jefferson University, Philadelphia, PA, 19107, USA. vxs039@jefferson.edu.
Abstract:
Assess the efficacy of deep convolutional neural networks (DCNNs) in detection of critical enteric feeding tube malpositions on radiographs. 5475 de-identified HIPAA compliant frontal view chest and abdominal radiographs were obtained, consisting of 174 x-rays of bronchial insertions and 5301 non-critical radiographs, including normal course, normal chest, and normal abdominal x-rays. The ground-truth classification for enteric feeding tube placement was performed by two board-certified radiologists. Untrained and pretrained deep convolutional neural network models for Inception V3, ResNet50, and DenseNet 121 were each employed. The radiographs were fed into each deep convolutional neural network, which included untrained and pretrained models. The Tensorflow framework was used for Inception V3, ResNet50, and DenseNet. Images were split into training (4745), validation (630), and test (100). Both real-time and preprocessing image augmentation strategies were performed. Receiver operating characteristic (ROC) and area under the curve (AUC) on the test data were used to assess the models. Statistical differences among the AUCs were obtained. p < 0.05 was considered statistically significant. The pretrained Inception V3, which had an AUC of 0.87 (95 CI; 0.80-0.94), performed statistically significantly better (p < .001) than the untrained Inception V3, with an AUC of 0.60 (95 CI; 0.52-0.68). The pretrained Inception V3 also had the highest AUC overall, as compared with ResNet50 and DenseNet121, with AUC values ranging from 0.82 to 0.85. Each pretrained network outperformed its untrained counterpart. (p < 0.05). Deep learning demonstrates promise in differentiating critical vs. non-critical placement with an AUC of 0.87. Pretrained networks outperformed untrained ones in all cases. DCNNs may allow for more rapid identification and communication of critical feeding tube malpositions.
Related Concept Videos
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Critical Thinking
Colleges and universities are...
Critical Thinking I
Critical Thinking II
Uterine Tubes

