Related Experiment Video
Updated: Jan 25, 2026

Versatility of Protocols for Resistance Training and Assessment Using Static and Dynamic Ladders in Animal Models
Published on: December 17, 2021
Influence of mini-screw diameter and loading conditions on static and dynamic assessments of bone-implant contact: An
Cristina R Exposto1, Ulas Oz2, Philip M Westgate3
1Department of Oral and Maxillofacial Surgery, Aalborg University Hospital, Aalborg, Denmark.
Objectives:
The goal was to compare static versus dynamic bone-implant interface histology of mini-screws and to evaluate its relation to diameter and load.
Setting And Sample Population:
Canine animal model.
Material And Methods:
Custom-machined, titanium alloy (Ti6AI4V) mini-screws (n = 70) of 1.60, 2.00, 3.00 and 3.75 mm diameter were placed into edentulous sites in five skeletally mature beagle dogs. Using a split-mouth design, no load (NL) was applied to one side while a 2N load (L) was applied by calibrated coil springs on the other side. Intravenous bone labels were administered 21 and 7 days prior to sacrifice. Dogs were euthanized 90 days after screw placement. Bone sections were analysed under bright-field and epifluorescent light. The region of interest was defined as the bone within the threads of the screws. The following parameters were quantified: (a) Static-bone volume/tissue volume (BV/TV %) and bone-implant contact (BIC, %); (b) Dynamic-labelled bone/bone volume (LB/BV, %), and dynamic BIC (DBIC, %).
Results:
BV/TV ranged from 71.2% to 85.0% of the screw surface. BIC ranged from 45.7% to 55.4% of the screw surface and was not affected by diameter (P = 0.66). In contrast, the percentage of DBIC did not vary with the applied load (P = 0.41); however, it correlated significantly with the diameter of the screw (P = 0.001).
Conclusion:
The percentage of DBIC that is actively remodelling increases with increasing diameter of the screw. Dynamic histomorphometry is more sensitive to detecting changes in bone-implant contact when compared to static measurements.
More Related Videos
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Static, Stagnation, Dynamic and Total Pressure
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Static Equilibrium - I