Related Experiment Video
Updated: Jan 25, 2026

In Vitro Impact Model to Generate Sublethal Chondrocyte Injury in Bovine Cartilage Explants
Published on: June 27, 2025
Evaluation of equine articular cartilage degeneration after mechanical impact injury using cationic contrast-enhanced
B B Nelson1, J T A Mäkelä2, T B Lawson3
1Equine Orthopaedic Research Center, Colorado State University, Fort Collins, CO, USA.
Objective:
Cationic agent contrast-enhanced computed tomography (cationic CECT) characterizes articular cartilage ex vivo, however, its capacity to detect post-traumatic injury is unknown. The study objectives were to correlate cationic CECT attenuation with biochemical, mechanical and histological properties of cartilage and morphologic computed tomography (CT) measures of bone, and to determine the ability of cationic CECT to distinguish subtly damaged from normal cartilage in an in vivo equine model.
Design:
Mechanical impact injury was initiated in equine femoropatellar joints in vivo to establish subtle cartilage degeneration with site-matched controls. Cationic CECT was performed in vivo (clinical) and postmortem (microCT). Articular cartilage was characterized by glycosaminoglycan (GAG) content, biochemical moduli and histological scores. Bone was characterized by volume density (BV/TV) and trabecular number (Tb.N.), thickness (Tb.Th.) and spacing (Tb.Sp.).
Results:
Cationic CECT attenuation (microCT) of cartilage correlated with GAG (r = 0.74, P < 0.0001), compressive modulus (Eeq) (r = 0.79, P < 0.0001) and safranin-O histological score (r = -0.66, P < 0.0001) of cartilage, and correlated with BV/TV (r = 0.37, P = 0.0005), Tb.N. (r = 0.39, P = 0.0003), Tb.Th. (r = 0.28, P = 0.0095) and Tb.Sp. (r = -0.44, P < 0.0001) of bone. Mean [95% CI] cationic CECT attenuation at the impact site (2215 [1987, 2443] Hounsfield Units [HUs]) was lower than site-matched controls (2836 [2490, 3182] HUs, P = 0.036). Clinical cationic CECT attenuation correlated with GAG (r = 0.23, P = 0.049), Eeq (r = 0.26, P = 0.025) and safranin-O histology score (r = -0.32, P = 0.0046).
Conclusions:
Cationic CECT (microCT) reflects articular cartilage properties enabling segregation of subtly degenerated from healthy tissue and also reflects bone morphometric properties on CT. Cationic CECT is capable of characterizing articular cartilage in clinical scanners.
More Related Videos
11:09Construction of a Realistic, Whole-Body, Three-Dimensional Equine Skeletal Model using Computed Tomography Data
Published on: February 25, 2021
07:57An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Self-Evaluation: Self-Enhancement and Self-Verification
Cationic Chain-Growth Polymerization: Mechanism
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Impact of Groups on Groups