Related Experiment Video
Updated: Jan 25, 2026

Visualizing and Quantifying Pharmaceutical Compounds within Skin using Coherent Raman Scattering Imaging
Published on: November 24, 2021
Quantitation of trace amorphous solifenacin succinate in pharmaceutical formulations by transmission Raman
Hirohito Terada1, Yusuke Hattori2, Tetsuo Sasaki3
1Musashino University, Graduate School of Pharmaceutical Sciences, 1-1-20, Shin-machi, Nishi-Tokyo City, Tokyo 202-8585, Japan; Pharmaceutical Research Center, OHARA Pharmaceutical Co., Ltd., 121-15, Toriino, Koka-cho, Koka-shi, Shiga 520-3403, Japan.
Abstract:
It is important to quantify amorphous solid in active pharmaceutical ingredients (API) of formulations to guarantee high-quality pharmaceutical products. In this study, we aimed to quantify amorphous solid in API by transmission Raman spectroscopy (TRS) and transmission near-infra-red spectroscopy (NIRS). To quantify the amount of trace amorphous solids contained in the API of a formulation, calibration curves of tablets containing 40% or 3% solifenacin succinate (SLFS) in the pharmaceutical formulations were prepared. The tablets varied in the ratio of amorphous solids in the API. TRS and NIRS were carried out with the calibration tablets and partial least square regression (PLSR) analysis was performed. Good results were obtained by both TRS and NIRS with the calibration model containing 40% SLFS. On the contrary, with the calibration model containing 3% SLFS, the PLSR analysis results using the TRS data were better than those using the NIRS data. The low content calibration model based on TRS showed good results with R2 of 0.999, RMSECV of 1.236, and LOD of 0.12. TRS can be used to specifically detect trace amorphous solids contained in the API of a formulation.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Pharmaceutical Equivalents
Factors Affecting Dissolution: Polymorphism, Amorphism and Pseudopolymorphism
Some polymorphic crystals possess lower aqueous solubility than their amorphous counterparts, leading to incomplete absorption. For instance, the oral suspension of Chloramphenicol, which...
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...