Related Experiment Video
Updated: Jan 25, 2026

Steady-state, Pre-steady-state, and Single-turnover Kinetic Measurement for DNA Glycosylase Activity
Published on: August 19, 2013
How steady is the STEADI? Inferential analysis of the CDC fall risk toolkit
Robert W Nithman1, Jennifer L Vincenzo2
1Doctor of Physical Therapy Program, College of Health Sciences, Midwestern University, Glendale, AZ, United States.
Introduction:
The CDC developed the STEADI toolkit to assist providers with incorporating fall risk screening, assessment of modifiable risk factors, and implementing evidence-based treatment strategies. The purpose of this study was two-fold: analyze the STEADI algorithm for strengths/weaknesses based upon inferential data and provide recommendations for additional research and possible limitations of the STEADI toolkit from a physical therapy perspective.
Methods:
This investigation employed a quantitative, cross-sectional cohort design collating data from community-dwelling and retirement-facility seniors (n = 77) from two regions of the U.S. Data is reported based upon descriptive statistics, correlation, and validity of the STEADI algorithm, its subcomponent tests, and self-reported fall data. All participants completed the Stay Independent Brochure (SIB) and the algorithm's mobility, balance, and lower extremity strength tests regardless of risk categorization.
Results:
Sensitivity of the STEADI with discriminating fallers and predicting future falls was better among community-dwellers (73-80%) versus the retirement facility-dwellers (56-62%). The STEADI demonstrated high false negative rates among those categorized as low risk as 57% community-dwellers and 24% facility-dwellers fell in the prior 12 months and several fell within 6 months following participation. Results suggest that it is important to conduct more than one mobility or balance screening test, and indicate that elevated STEADI risk classification was not associated with advancing age.
Conclusions:
Outcomes from this study suggest that cut-off scores and the selection of functional fall screening tests, as well as the relative weights and scoring of items on the SIB/3KQ be reevaluated to maximize discriminate and predictive validity of the algorithm.
Related Concept Videos
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous...
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Steady, Laminar Flow Between Parallel Plates
Steady, Laminar Flow in Circular Tubes

