Related Experiment Video
Updated: Jan 25, 2026

Engineering Biological-Based Vascular Grafts Using a Pulsatile Bioreactor
Published on: June 14, 2011
CardioFAN: open source platform for noninvasive assessment of pulse transit time and pulsatile flow in hyperelastic
Yashar Seyed Vahedein1, Alexander S Liberson2
1Rochester Institute of Technology, 76 Lomb Memorial Drive, Rochester, NY, 14623, USA. Yashar.Seyed.Vahedein@rit.edu.
Abstract:
A profound analysis of pressure and flow wave propagation in cardiovascular systems is the key in noninvasive assessment of hemodynamic parameters. Pulse transit time (PTT), which closely relates to the physical properties of the cardiovascular system, can be linked to variations of blood pressure and stroke volume to provide information for patient-specific clinical diagnostics. In this work, we present mathematical and numerical tools, capable of accurately predicting the PTT, local pulse wave velocity, vessel compliance, and pressure/flow waveforms, in a viscous hyperelastic cardiovascular network. A new one-dimensional framework, entitled cardiovascular flow analysis (CardioFAN), is presented to describe the pulsatile fluid-structure interaction in the hyperelastic arteries, where pertaining hyperbolic equations are solved using a high-resolution total variation diminishing Lax-Wendroff method. The computational algorithm is validated against well-known numerical, in vitro and in vivo data for networks of main human arteries with 55, 37 and 26 segments, respectively. PTT prediction is improved by accounting for hyperelastic nonlinear waves between two arbitrary sections of the arterial tree. Consequently, arterial compliance assignments at each segment are improved in a personalized model of the human aorta and supra-aortic branches with 26 segments, where prior in vivo data were available for comparison. This resulted in a 1.5% improvement in overall predictions of the waveforms, or average relative errors of 5.5% in predicting flow, luminal area and pressure waveforms compared to prior in vivo measurements. The open source software, CardioFAN, can be calibrated for arbitrary patient-specific vascular networks to conduct noninvasive diagnostics.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Phase Transitions
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...

