Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
2.8K
Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI
Joshua F P van Amerom1, David F A Lloyd1,2, Maria Deprez1
1School of Biomedical Engineering & Imaging Sciences, King's College London, London, United Kingdom.
Magnetic Resonance in Medicine
|May 14, 2019
Summary
This study presents a new MRI method for clear 4D fetal heart imaging, overcoming motion challenges. This advanced visualization aids in comprehensive fetal cardiac assessment.
Area of Science:
- Medical Imaging
- Cardiovascular Imaging
- Fetal Medicine
Background:
- Maternal and fetal motion significantly challenge fetal heart MRI.
- Accurate visualization of the fetal heart and great vessels is crucial for prenatal diagnosis.
Purpose of the Study:
- To develop an MRI framework for volumetric cine visualization of the fetal heart and great vessels.
- To address challenges posed by maternal and fetal motion during imaging.
Main Methods:
- Utilized a highly-accelerated multi-planar real-time balanced steady-state free precession acquisition.
- Employed retrospective image-domain techniques for motion correction, cardiac synchronization, and outlier rejection.
- Validated the framework with a numerical phantom and evaluated in 20 fetal subjects (23-33 weeks gestational age).
Main Results:
- Achieved four-dimensional (4D) depiction of the fetal heart and great vessels.
- Reconstructed 4D data allowed visualization in any 2D plane, independent of scan plane prescription.
- The framework demonstrated robustness in fetal data and simulations, reliably recovering spatial and temporal features.
- Reconstruction was automated, requiring only user-specified masks.
Conclusions:
- The developed MRI framework shows promise for motion-compensated 4D assessment of the fetal heart and great vessels.
- This technique has the potential to serve as an adjunct to ultrasound or complement other MRI methods for comprehensive fetal cardiac evaluation.
Related Concept Videos
Planar Rigid-Body Motion
1.0K
Understanding the movement of a rigid body in planar motion involves recognizing that every particle within this body is traversing a path that maintains a consistent distance from a specific plane. This concept is fundamental in the study of physics and mechanical engineering, and it allows us to comprehend better how objects move in space.
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
1.0K
Imaging Studies I: CT and MRI
839
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
839
Real Time RT-PCR
64.9K
Real-time reverse transcription-polymerase chain reaction, or Real-time RT-PCR, is an analytical tool used to determine the expression level of target genes. The method involves converting mRNA to complementary DNA with the help of an enzyme known as reverse transcriptase, followed by the PCR amplification of the cDNA. These two processes can be performed simultaneously in a single tube or separately as a two-step reaction.
The real-time quantification of the number of amplified products is...
The real-time quantification of the number of amplified products is...
64.9K
Crystal Field Theory - Tetrahedral and Square Planar Complexes
48.3K
Tetrahedral Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
48.3K
Distance Corrections
285
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
285
Power Factor Correction
510
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
510