Related Experiment Video
Updated: Jan 25, 2026

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Influence of Er;Cr:YSGG Laser on Shear Bond Strength and Color Stability of Lithium Disilicate Ceramics: An In Vitro
Fahim Vohra1, Nawaf Labban2, Abeer Al-Hussaini3
11Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Eng. Abdullah Bugshan Research Chair for Dental and Oral Rehabilitation, Riyadh, Saudi Arabia.
Abstract:
The aim of this study was to assess the effect of Er;Cr:YSGG laser parameters (power and frequency) on the bond strength and color stability of lithium disilicate (LD) ceramics. One hundred ten specimens of LD ceramic were fabricated following heat pressed technique. Fifty disks were randomly distributed into five groups according to types of surface treatment [hydrofluoric (HF) acid, L1S L2S, L1D, and L2D]. For all laser-treated groups, bond preparation settings were used with a gold hand piece using a MZ10 tip (Er;Cr:YSGG, water lase I plus; Biolase). After surface treatment, adhesive bond was applied, and after photopolymerization, a composite buildup was performed. To evaluate shear bond strength, a controlled force was applied until failure using a universal testing machine. Color stability was assessed for six groups (HF, L1S L2S, L1D, L2D, and control) of LD ceramic (shade A1, LT translucency) through the CIE L*a*b* system. Three specimens from each of the six groups were selected randomly for assessment of surface topography using scanning electron microscopy. Means and standard deviations were compared using analysis of variance and Tukey's post hoc test (p < 0.05). The maximum and minimum mean bond strength were shown by the L2D group 19.95 ± 1.014 and L1S group specimens 14.68 ± 0.863, respectively. Highest mean ΔE was found in L2S group 8.17 ± 2.10 and the lowest mean ΔE was found in control group (no treatment) 0.11 ± 0.05. LD specimens lased (Er;Cr:YSGG) with 3.75 W power and 15 Hz frequency for 4 min showed bond strength comparable with HF acid samples, and color changes within acceptable range (ΔE 1.17). Laser treatment (Er;Cr:YSGG) at 3.75 W power and 15 Hz frequency for 4 min of LD ceramics appears to be clinically efficient, showing acceptable bond strength and color stability.
More Related Videos
Related Concept Videos
Bonding and Strength of Aggregate
Bond Energies and Bond Lengths
Ionic Bonding and Electron Transfer
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Complexation Equilibria: Factors Influencing Stability of Complexes
Covalent Bonding and Lewis Structures

