Related Experiment Video
Updated: Jan 25, 2026

Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
Effect of a New Model-Based Reconstruction Algorithm for Evaluating Early Peripheral Lung Cancer With Submillisievert
Jia Yongjun, Zhai Bingying1, He Taiping
1Department of Critical Care Medicine, Xianyang Hospital of Yan'an University, Xianyang, China.
Objective:
The aim of this study was to compare a new model-based iterative reconstruction algorithm with either spatial and density resolution balance (MBIRSTND) or spatial resolution preference (MBIRRP20) with the adaptive statistical iterative reconstruction (ASIR) in evaluating early small peripheral lung cancer (SPLC) with submillisievert chest computed tomography (CT).
Methods:
Low-contrast and spatial resolutions were assessed in a phantom and with 30 pathologically confirmed SPLC patients. Images were reconstructed using 40% ASIR, MBIRSTND, and MBIRRP20. Computed tomography value and image noise were measured by placing the regions of interest on back muscle and subcutaneous fat at 3 levels. Two radiologists used a 4-point scale (1, worst, and 4, best) to rate subjective image quality in 3 aspects: image noise, nodule imaging signs, and nodule internal clarity.
Results:
The phantom study revealed an improved detectability of low-contrast targets and small objects for MBIRSTND and MBIRRP20 compared with ASIR. The effective dose for patient scans was 0.88 ± 0.83 mSv. There was no significant difference in CT value between the 3 reconstructions (P > 0.05), but MBIRSTND and MBIRRP20 significantly reduced image noise compared with ASIR (P < 0.05): 15.69 ± 1.83 HU and 29.97 ± 3.84 HU versus 51.06 ± 11.02 HU in the back muscle, and 15.96 ± 3.07 HU and 27.37 ± 3.88 HU versus 38.04 ± 8.87 HU in subcutaneous fat, respectively. Among the 3 reconstructions, MBIRSTND was the best in reducing image noise and identifying the internal compositions of cancer nodules, and MBIRRP20 was the best in analyzing the internal and external signs of pulmonary nodules.
Conclusions:
Submillisievert chest CT reconstructed with MBIRSTND and MBIRRP20 provides superior images for the detailed analyses of SPLC compared with ASIR.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...

