Proposed safe apnea test using positive end-expiratory pressure valve and short-term blood gas analysis:
Jin Park1, Young-Joo Lee2, Kyung Sook Hong3
1Department of Neurology and Critical Care Medicine.
Abstract:
The apnea test is an essential examination for the determination of brain death; however, hypotension, hypoxemia, and other complications during the apnea test can affect the stability of brain-dead patients, as well as organ function for recipients. Therefore, it is necessary to establish standard guidelines for apnea testing.The modified apnea test (MAT) comprises delivery of 100% oxygen through the endotracheal tube connected to manual resuscitator (Ambu bag) with the positive end-expiratory pressure (PEEP) valve after disconnection of the mechanical ventilator for maintenance of PEEP. Forty-nine instances of the conventional apnea test (CAT) were performed in 25 brain-dead patients; 77 instances of the MAT were performed in 39 brain-dead patients.The mean duration of the apnea test was 3.5 ± 1.4 minutes in the CAT group and 3.0 ± 1.2 minutes in the MAT group. There were no significant changes in PaCO2, PaO2, or pH between the CAT and MAT groups (P = .341, .593, and .503, respectively). In overweight patients (body mass index ≥ 23 kg/m), MAT prevented dramatic reductions in PaO2 and SaO2 (P < .05 for both). In the patients who had hypoxic brain injury due to hanging, differences in PaO2 and SaO2 in the MAT group were significantly smaller than in the CAT group (P < .05).Although MAT, which was invented to maintain PEEP, was not efficient for all brain-dead patients, it could be helpful in selected patient groups, such as overweight patients or those who had hypoxic injury due to hanging. And clinicians should consider short-term apnea test to avoid unnecessarily prolonged hypoxemia.
Related Concept Videos
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...