Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
Published on: September 5, 2018
Quantification of pulmonary/systemic shunt ratio by single-acquisition phase-contrast cardiovascular magnetic
Terence Sean Dunn1, Pratik Patel1, Bassem Abazid1
1Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama.
Purpose:
Phase-contrast cardiovascular magnetic resonance (PC-CMR) quantification of intracardiac shunt (measuring the pulmonary to systemic flow ratio, Qp/Qs) is typically determined by measuring flow through planes perpendicular the pulmonary trunk (PA) and ascending aorta (Ao). This method is subject to error from presence of background velocity offsets and requires two scan acquisitions. We evaluated an alternate PC-CMR technique for quantifying Qp/Qs using a single modified plane that encompasses both the PA and Ao.
Material And Methods:
In 53 patients evaluated for intracardiac shunting, PC-CMR measurement in the individual Ao and PA planes and also in a single-acquisition plane was obtained and Qp/Qs calculated by each method. Bland-Altman analysis was performed to evaluate the agreement between the two methods.
Results:
The 95% confidence limits of agreement ranged from -0.52 to +0.34 indicating good agreement between the two methods. There was excellent agreement on the clinically relevant threshold value of Qp/Qs ratio of 1.5 (representing criteria for surgical correction of shunt).
Conclusions:
Qp/Qs determined from the single-acquisition approach agrees well with that of the individual PA and Ao method and offers potential improved accuracy (due to background velocity offset).
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...