Evaluation of four injection profiles for uniform contrast-enhanced signal intensity profiles in MR angiography
Jeffrey H Maki1,2, Gregory J Wilson2,3, Toshimasa J Clark1
1The Department of Radiology, University of Colorado Denver, Aurora, Colorado, USA.
Background:
Gadolinium concentration variation during acquisition of contrast-enhanced MR angiography (CE-MRA) may lead to artifacts.
Purpose:
To compare signal intensity (SI) profiles of four different contrast agent injection strategies during CE-MRA with the goal of minimizing SI variation during acquisition.
Study Type:
Prospective.
Subjects:
Forty subjects randomized to receive one of four injection profiles of gadobenate dimeglumine (0.1 mmol/kg), either undiluted (0.5 M) or diluted to 40 ml total volume. Tested profiles: 1) nondiluted single-phase ("standard" NS; 1.6 ml/s), 2) diluted single-phase (DS; 1.6 ml/s), 3) diluted biphasic (DB; 9 ml @ 3.3 ml/s, 29 ml @ 1.4 ml/s), 4) patient-tailored protocol using linear prediction (DT).
Field Strength/Sequence:
Time-resolved SI measured at 3T with spoiled gradient echo sequences having analogous parameters to those of CE-MRA.
Assessment:
Plateau arrival time, rise time, duration, peak and tail SI, plateau quality (sum of squared residuals; SSR), average SI for each injection type derived were used.
Statistical Test:
Two-tailed t-test.
Results:
Peak SI, arrival, and rise times were not significantly different between groups, excepting peak SI DB slightly > DS (P = 0.042). Duration of NS vs. the diluted groups was significantly shorter (all P < 0.0001), and DS duration was significantly shorter than that of DT and DB (NS 11.4 ± 3.5 vs. DS 22.9 ± 4.3, DB 25.4 ± 2.3, DT 28.3 ± 4.1 sec). Quality (SSR) of the 20-second plateau was significantly better for DS, DB, DT as compared with NS (all P < 0.001).
Data Conclusion:
Three different strategies to power-inject diluted gadobenate dimeglumine targeting a 20-second plateau produced SI profiles with longer duration, more consistent plateau, and no significant loss in peak SI. Such injection profiles may provide more uniform SI during CE-MRA, potentially reducing blurring artifacts.
Level Of Evidence:
2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1808-1816.
Related Concept Videos
Ribosome Profiling
Applications of ribosome profiling
Ribosome profiling has many applications, including in vivo monitoring of translation inside a particular organ or tissue type and quantifying new protein synthesis levels.
The technique...
Self-Evaluation: Self-Enhancement and Self-Verification
Taping Over Different Ground Profiles
Profile Leveling and Cross Sections
Drug Dissolution: Requirements and Profile Comparison
Uniform Distribution
Two essential properties of this distribution are