Related Experiment Video
Updated: Jan 24, 2026

A Swimming-Induced Zebrafish Exercise Apparatus for Versatile Training Approaches
Published on: October 18, 2024
Predictors and reproducibility of exercise-induced bronchoconstriction in cold air
Melanie Dreßler1, Theresa Friedrich2, Natali Lasowski2
1Division of Pulmonology, Allergy and Cystic Fibrosis, Department of Paediatric and Adolescent medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany. melanie.dressler@kgu.de.
Background:
Physical activity is an important part of life, and hence exercise-induced bronchoconstriction (EIB) can reduce the quality of life. A standardized test is needed to diagnose EIB. The American Thoracic Society (ATS) guidelines recommend an exercise challenge in combination with dry air. We investigated the feasibility of a new, ATS guidelines conform exercise challenge in a cold chamber (ECC) to detect EIB. The aim of this study was to investigate the surrogate marker reaction to methacholine, ECC and exercise challenge in ambient temperature for the prediction of a positive reaction and to re-evaluate the reproducibility of the response to an ECC.
Methods:
Seventy-eight subjects aged 6 to 40 years with suspected EIB were recruited for the study. The subjects performed one methacholine challenge, two ECCs, and one exercise challenge at an ambient temperature. To define the sensitivity and specificity of the predictor, a receiver-operating characteristic curve was plotted. The repeatability was evaluated using the method described by Bland and Altman (95% Limits of agreement).
Results:
The following cut-off values showed the best combination of sensitivity and specificity: the provocation dose causing a 20% decrease in the forced expiratory volume in 1 s (PD20FEV1) of methacholine: 1.36 mg (AUC 0.69, p < 0.05), the maximal decrease in FEV1 during the ECC: 8.5% (AUC 0.78, p < 0.001) and exercise challenges at ambient temperatures: FEV1 5.2% (AUC 0.64, p = 0.13). The median decline in FEV1 was 14.5% (0.0-64.2) during the first ECC and 10.7% (0.0-52.5) during the second ECC. In the comparison of both ECCs, the Spearman rank correlation of the FEV1 decrease was r = 0.58 (p < 0.001). The 95% limits of agreement (95% LOAs) for the FEV1 decrease were - 17.7 to 26.4%.
Conclusions:
The surrogate markers PD20FEV1 of methacholine and maximal decrease in FEV1 during ECC can predict a positive reaction in another ECC, whereas the maximal FEV1 decrease in an exercise challenge at an ambient temperature was not predictive. Compared with previous studies, we can achieve a similar reproducibility with an ECC.
Clinical Trial Registration:
NCT02026492 (retrospectively registered 03/Jan/2014).
More Related Videos
Related Concept Videos
Responses to Heat and Cold Stress
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Air-entraining Agents
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...

